Drawing → BOQ
← Mindmapwhat the drawings said

Central Tendon Duct

1 page · 1 crop · ×1 · superstructure

Matched toPrestressing Ductbridge.ancillary_system.prestressing_system.ducton “tendon duct

0 of 3 required measurements have a number
The class asks forUnitA reading with that nameFrom
LengthLm/mmno reading by that name
Instance CountNcountno reading by that name
Material TypeMATno reading by that name

Paired on the measurement’s name only, which cannot know that three span lengths sum to the deck length. Step 3 works these out properly for every item it matches — reading every crop behind the item, deriving what the drawings imply and showing its arithmetic. This item has not had that pass yet; the button runs it for this one.

How the sheets named it

Central stem / tendon duct

Notes on the sheets that carry it

  • p11DIMENSIONS ALONG BEAM
  • p11INDICATES 1/2" DIAMETER PRESTRESSED STRANDS.
  • p11MAINTAIN 1" MINIMUM CLEARANCE UNLESS OTHERWISE SHOWN.

Every crop it was read in — the drawing beside what the model took off it

Page 11

crop

p11_r02 section at end

page 11 · gdot_drawing_0a6d24ffdd874879a37c7122f1fd8bef_p11_r02_section_at_end
Original
p11_r02 section at end
{
  "view": "Section",
  "objects": [
    {
      "name": "Footing / Pedestal",
      "tag": "",
      "shape": "irregular polygon",
      "material": "reinforced concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "Prestressed strands",
      "tag": "",
      "shape": "circular (dots along line)",
      "material": "steel",
      "count": null,
      "note": "pattern indicates 1/2 inch diameter prestressed strands"
    },
    {
      "name": "Central stem / tendon duct",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 1,
      "note": ""
    },
    {
      "name": "Perforated base region",
      "tag": "",
      "shape": "irregular polygon with perforations",
      "material": "reinforced concrete",
      "count": 1,
      "note": "dotted area representing perforations / voids in base"
    }
  ],
  "measurements": [
    {
      "label": "Top left horizontal dimension",
      "value": "1'-4\"",
      "unit": "ft-in",
      "appliesTo": "Section at midpoint (top dimension)"
    },
    {
      "label": "Interior vertical dimension",
      "value": "550",
      "unit": "",
      "appliesTo": "Section at midpoint interior vertical"
    },
    {
      "label": "Interior spacing",
      "value": "7\"",
      "unit": "in",
      "appliesTo": "Section at midpoint interior spacing"
    },
    {
      "label": "Bottom width spacing",
      "value": "9 SPACES AT 2\"",
      "unit": "",
      "appliesTo": "Bottom width spacing"
    },
    {
      "label": "Overall bottom width",
      "value": "1'-10\"",
      "unit": "ft-in",
      "appliesTo": "Bottom width overall"
    },
    {
      "label": "Right section height",
      "value": "2'-7\"",
      "unit": "ft-in",
      "appliesTo": "Section at end height"
    }
  ],
  "notes": [
    "DIMENSIONS ALONG BEAM",
    "INDICATES 1/2\" DIAMETER PRESTRESSED STRANDS.",
    "MAINTAIN 1\" MINIMUM CLEARANCE UNLESS OTHERWISE SHOWN."
  ],
  "labels": [
    "SECTION AT MIDPOINT",
    "SECTION AT END"
  ],
  "description": "Cross-section views (Section at midpoint and Section at end) from Sheet page 11 showing a reinforced concrete footing/pedestal with a vertical central tendon duct and prestressed strands, including a perforated base area and surrounding wing-like sections."
}

p11_r02 section at endSection

  • Central stem / tendon duct×1rectangularreinforced concrete

1'-4" ft-in Top left horizontal dimension550 Interior vertical dimension7" in Interior spacing9 SPACES AT 2" Bottom width spacing1'-10" ft-in Overall bottom width2'-7" ft-in Right section height