Matched toPier Capbridge.substructure.pier_system.pier_capon “Pier Cap”
| The class asks for | Unit | A reading with that name | From |
|---|---|---|---|
| LengthL | m/mm | no reading by that name | |
| WidthW | m/mm | 3'-0" | p13 · p13_r05 |
| ThicknessT | m/mm | no reading by that name | |
| Instance CountN | count | no reading by that name | |
| Concrete Gradefck | — | no reading by that name |
Paired on the measurement’s name only, which cannot know that three span lengths sum to the deck length. Step 3 works these out properly for every item it matches — reading every crop behind the item, deriving what the drawings imply and showing its arithmetic. This item has not had that pass yet; the button runs it for this one.
How the sheets named it
Every dimension read for it6
- 6'-0"6'-0" MIN.not attributedp13 · p13_r05 2 0 min
- 3'-0"3'-0"not attributedp13 · p13_r05 2 0 min
- 2'-0"2'-0" MIN.not attributedp13 · p13_r05 2 0 min
- 3'-0"cap widthp13 · p13_r05
- 2'-0" MIN.cap heightp13 · p13_r05
- 2'-0" MIN.cap heightp17 · p17_r05 2 0 min
Notes on the sheets that carry it
- p13SECTION AT END PNT AND WALL
Every crop it was read in — the drawing beside what the model took off it
Page 13
p13_r05 2 0 minDetail
- concrete cap×1rectangularreinforced concrete
6'-0" 6'-0" MIN.3'-0" 3'-0"2'-0" 2'-0" MIN.
p13_r05Section
- cap×1rounded rectanglereinforced concrete
6'-0" MIN. overall length (min)3'-0" cap width2'-0" MIN. cap height
Page 17
p17_r05 2 0 minPlan
- CAP×1rectangular with rounded left cornersconcrete
6'-0" MIN. overall length (BFPR to far edge)3'-0" offset to cap left edge2'-0" MIN. cap height
p17_r05Plan
- CAP×1rectangularreinforced concrete
6'-0" MIN. 6'-0" MIN.3'-0" ft 3'-0"2'-0" MIN. 2'-0" MIN.