Drawing → BOQ
← Mindmapwhat the drawings said

Gutter

1 page · 1 crop · ×2 · drainage

⚠ No class in the bridge ontology fits this itemAdd a class

The ontology would need a bridge gutter drainage component class.

Notes on the sheets that carry it

  • p1POINT OF MIN. VERT. CLEARANCE
  • p1FUTURE POINT OF MIN. VERT. CLEARANCE
  • p1TEMPORARY SHORING AS NECESSARY, TYP.
  • p1TO BE REMOVED
  • p1MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN
  • p1CHAIN LINK WIRE FENCE, TYP.

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r01

page 1 · other_p01_r01
Original
p01_r01
{
  "view": "Plan",
  "objects": [
    {
      "name": "Bridge deck / superstructure outline",
      "tag": "LEFT BRIDGE",
      "shape": "rectangular, skewed ends",
      "material": "",
      "count": 1,
      "note": "Upper bridge shown in plan between Walls 1 and 2."
    },
    {
      "name": "Bridge deck / superstructure outline",
      "tag": "RIGHT BRIDGE",
      "shape": "rectangular, skewed ends",
      "material": "",
      "count": 1,
      "note": "Lower bridge shown in plan between Walls 1 and 2."
    },
    {
      "name": "Wall",
      "tag": "WALL 1",
      "shape": "skewed rectangular wall line",
      "material": "",
      "count": 2,
      "note": "Front face called out at the left end of each bridge."
    },
    {
      "name": "Wall",
      "tag": "WALL 2",
      "shape": "skewed rectangular wall line",
      "material": "",
      "count": 2,
      "note": "Front face called out at the right end of each bridge."
    },
    {
      "name": "Bent",
      "tag": "BENT 1L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 2L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 3L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 4L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 1R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 2R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 3R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 4R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Gutter",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Gutter limits are dimensioned on both bridge plans."
    },
    {
      "name": "Central of Georgia Railroad Company existing track",
      "tag": "",
      "shape": "parallel linear tracks",
      "material": "",
      "count": null,
      "note": "Crosses beneath the bridge plans."
    },
    {
      "name": "Future access road",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Temporary shoring",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Shown near the railroad at the right side."
    },
    {
      "name": "Chain link wire fence",
      "tag": "",
      "shape": "fence line",
      "material": "chain link wire",
      "count": null,
      "note": "Only a partial lower-plan depiction is visible."
    }
  ],
  "measurements": [
    {
      "label": "Minimum dimension",
      "value": "12'-1\" MIN.",
      "unit": "",
      "appliesTo": "Central of Georgia Railroad Company existing track / future access road area"
    },
    {
      "label": "Dimension",
      "value": "74'-7 15/16\"",
      "unit": "",
      "appliesTo": "Upper bridge plan"
    },
    {
      "label": "Bearing / direction",
      "value": "N 2°-23'-16.71\" E",
      "unit": "",
      "appliesTo": "Upper bridge plan"
    },
    {
      "label": "Dimension",
      "value": "75'-10 15/16\"",
      "unit": "",
      "appliesTo": "Upper bridge plan"
    },
    {
      "label": "Minimum vertical clearance offset",
      "value": "1'-9½\"",
      "unit": "",
      "appliesTo": "Point of min. vert. clearance"
    },
    {
      "label": "Dimension",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "Point of min. vert. clearance"
    },
    {
      "label": "Gutter-to-gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "Upper bridge"
    },
    {
      "label": "Gutter-to-out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "Upper bridge"
    },
    {
      "label": "Width",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "Upper bridge"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "Walls / bridge ends"
    },
    {
      "label": "Station",
      "value": "STA. 18+16.85",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "Station",
      "value": "STA. 303+80.83",
      "unit": "",
      "appliesTo": "℄ Central of Georgia Railroad Company"
    },
    {
      "label": "Begin bridge station",
      "value": "STA. 17+23.00",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Station",
      "value": "STA. 17+29.07",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Bearing / direction",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "Station",
      "value": "STA. 19+08.93",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "End bridge station",
      "value": "STA. 19+15.00",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Width",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Minimum dimension",
      "value": "14'-1\" MIN.",
      "unit": "",
      "appliesTo": "Lower bridge / future point of min. vert. clearance"
    },
    {
      "label": "Gutter-to-gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Gutter-to-out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Width",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Dimension",
      "value": "15'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge clearance area"
    },
    {
      "label": "Minimum horizontal clearance",
      "value": "25'-8\"",
      "unit": "",
      "appliesTo": "Face of column"
    },
    {
      "label": "Minimum horizontal clearance",
      "value": "36'-4\"",
      "unit": "",
      "appliesTo": "Face of column"
    },
    {
      "label": "Total length of bridge",
      "value": "192'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "82'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Proposed vertical grade",
      "value": "+5.4180%",
      "unit": "",
      "appliesTo": "SR 21 PGL"
    },
    {
      "label": "Proposed vertical grade",
      "value": "+5.4443%",
      "unit": "",
      "appliesTo": "SR 21 PGL"
    }
  ],
  "notes": [
    "POINT OF MIN. VERT. CLEARANCE",
    "FUTURE POINT OF MIN. VERT. CLEARANCE",
    "TEMPORARY SHORING AS NECESSARY, TYP.",
    "TO BE REMOVED",
    "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN",
    "CHAIN LINK WIRE FENCE, TYP."
  ],
  "labels": [
    "℄ FUTURE ACCESS ROAD",
    "℄ CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK",
    "TO PERKINS",
    "TO US 25/SR 121",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "℄ SR 21",
    "TO GA HIGHWAY 23",
    "RR R/W",
    "TO MILLEN",
    "PT #3",
    "RRMP D-0080.54",
    "PLAN",
    "BENT ELEVATIONS",
    "LOCATION",
    "BENT NO.",
    "LEFT BRIDGE",
    "RIGHT BRIDGE",
    "PROPOSED VERT",
    "SR 21 PGL",
    "N."
  ],
  "description": "This crop is a plan view of two parallel bridge structures carrying SR 21 across the Central of Georgia Railroad Company existing track. It shows the left- and right-bridge bent locations, wall front faces, gutters, roadway centerlines, clearance callouts, railroad/right-of-way features, and partial bridge-length dimensions. A partial bent-elevations table and portions of proposed vertical-profile graphics are visible at the right and lower edges."
}

p01_r01Plan

  • Gutter×2linearGutter limits are dimensioned on both bridge plans.

12'-1" MIN. Minimum dimension74'-7 15/16" DimensionN 2°-23'-16.71" E Bearing / direction75'-10 15/16" Dimension1'-9½" Minimum vertical clearance offset6'-0" Dimension40'-0" Gutter-to-gutter width43'-7" Gutter-to-out width+23 more