⚠ No class in the bridge ontology fits this itemAdd a class
The ontology would need a pile connection component class.
Notes on the sheets that carry it
- p14NOTES:
- p141. SEE BRIDGE SHEET NO. 16 FOR CAP, COLUMN AND FOOTING SECTIONS.
- p142. BARS 422 NOT SHOWN.
- p143. EXTEND BARS 1121A 3'-6" INTO CAP.
- p14MECHANICAL COUPLER, TYP. SEE SPECIAL PROVISION 511
- p14* REQUIRED CONSTRUCTION JOINT. AT CONTRACTOR'S OPTION, CONSTRUCTION JOINT MAY BE RELOCATED TO TOP OF FOOTING.
- p14PILES ARE DESIGNED FOR A MAXIMUM FACTORED AXIAL LOAD OF 237 KIPS.
Every crop it was read in — the drawing beside what the model took off it
Page 14
crop
p14_r02 title blockElevation
- pile connectionDetail shows reinforcing bars connected above an H-pile.
44-421 cap reinforcement spacingAT EQ. SPS. cap reinforcement spacingEL. 185.78 elevationEL. 185.23 elevationEL. 185.96 elevationEL. 185.41 elevationEL. 186.10 elevationEL. 185.55 elevation+63 more