Drawing → BOQ
← Mindmapwhat the drawings said

Wall

3 pages · 11 crops · ×16 · substructure

⚠ No class in the bridge ontology fits this itemAdd a class

The ontology would need a generic structural wall component class.

How the sheets named it

WALL 1WALL 2WALL NO. 1WALL NO. 2

Every dimension read for it4

  • 6'-0"minimum horizontal distance from B.F.P.R. reference to wall referencenot attributedp13 · p13_r05 2 0 min
  • 6'-0" MIN.minimum horizontal dimensionnot attributedp13 · p13_r05
  • 6'-0" MIN.minimum horizontal distance from B.F.P.R. to wall reference linep17 · p17_r05 2 0 min
  • 6'-0" MIN.minimum horizontal dimension from B.F.P.R. referencenot attributedp17 · p17_r05

Notes on the sheets that carry it

  • p1FRONT FACE OF WALL 1
  • p1FRONT FACE OF WALL 2
  • p1ℂ FUTURE ACCESS ROAD
  • p1ℂ FUTURE TRACK
  • p1ℂ CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK
  • p112'-1" MIN.
  • p1POINT OF MIN. VERT. CLEARANCE
  • p1FUTURE POINT OF MIN. VERT. CLEARANCE
  • p1AHEAD
  • p1TO PERKINS
  • p1TO US 25/SR 121
  • p1PGL WESTBOUND
  • p1PGL EASTBOUND
  • p1ℂ BENT 2L / ℂ BENT 2R
  • p1ℂ BENT 3L / ℂ BENT 3R
  • p1B.F.P.R. BENT 1L / 1R / 4L / 4R
  • p181°-20'-05.0", TYP.
  • p1STA. 18+16.85, ℂ SR 21 = STA. 303+80.83, ℂ CENTRAL OF GEORGIA RAILROAD COMPANY
  • p1BEGIN BRIDGE STA. 17+23.00
  • p1STA. 17+29.07
  • p1RRMP D-0080.54
  • p1ℂ SR 21
  • p1N 83°-43'-21.7" E
  • p1PT#3
  • p1END BRIDGE STA. 19+15.00
  • p1TEMPORARY SHORING AS NECESSARY, TYP.
  • p1TO BE REMOVED
  • p1TO GA HIGHWAY 23
  • p1RR R/W
  • p1TO MILLEN
  • p1MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN
  • p1CHAIN LINK WIRE FENCE, TYP.
  • p1TOTAL LENGTH OF BRIDGE = 192'-0" ***
  • p1FRONT FACE OF WALL NO. 1
  • p1FRONT FACE OF WALL NO. 2
  • p1EL. 151.00, TYP.
  • p1APPROXIMATE EXISTING GROUNDLINE
  • p1FUTURE GROUNDLINE
  • p13FRONT OF WALL
  • p13FRONT FA... OF WALL (partial)

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r01 plan

page 1 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p01_r01_plan
Original
p01_r01 plan
{
  "view": "Plan",
  "objects": [
    {
      "name": "Bent",
      "tag": "BENT 1 (1L/1R)",
      "shape": "linear (cap over columns, not detailed)",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Shown as centerline/B.F.P.R. bent lines at each end of bridge; B.F.P.R. = Back Face of Pile/Pier Row presumably"
    },
    {
      "name": "Bent",
      "tag": "BENT 2 (2L/2R)",
      "shape": "linear",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Centerline shown, skewed to roadway"
    },
    {
      "name": "Bent",
      "tag": "BENT 3 (3L/3R)",
      "shape": "linear",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Centerline shown, skewed to roadway"
    },
    {
      "name": "Bent",
      "tag": "BENT 4 (4L/4R)",
      "shape": "linear",
      "material": "reinforced concrete",
      "count": 2,
      "note": "Centerline/B.F.P.R. shown at end of bridge"
    },
    {
      "name": "Wall",
      "tag": "WALL 1",
      "shape": "rectangular/retaining wall face",
      "material": "unspecified (likely reinforced concrete)",
      "count": 2,
      "note": "Front face of Wall 1 shown at both approaches; one wall noted 'TO BE REMOVED'"
    },
    {
      "name": "Wall",
      "tag": "WALL 2",
      "shape": "rectangular/retaining wall face",
      "material": "unspecified",
      "count": 2,
      "note": "Front face of Wall 2 shown at both far ends"
    },
    {
      "name": "Chain link wire fence",
      "tag": "",
      "shape": "linear fence",
      "material": "chain link/wire",
      "count": null,
      "note": "Called out at bottom partial elevation, typical along bridge"
    },
    {
      "name": "Temporary shoring",
      "tag": "",
      "shape": "unspecified",
      "material": "unspecified",
      "count": null,
      "note": "Noted 'as necessary, typ.' near end bridge station"
    },
    {
      "name": "Railroad track (existing)",
      "tag": "",
      "shape": "linear",
      "material": "steel rail",
      "count": 1,
      "note": "Central of Georgia Railroad Company existing track shown crossing under bridge"
    },
    {
      "name": "Future track",
      "tag": "",
      "shape": "linear",
      "material": "unspecified",
      "count": 1,
      "note": "Centerline of future track shown, not yet constructed"
    },
    {
      "name": "Future access road",
      "tag": "",
      "shape": "linear",
      "material": "unspecified",
      "count": 1,
      "note": "Centerline shown, planned"
    }
  ],
  "measurements": [
    {
      "label": "Total length of bridge",
      "value": "192'-0\"",
      "unit": "ft-in",
      "appliesTo": "Bridge overall"
    },
    {
      "label": "Span 1 length",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Bent 1 to Bent 2"
    },
    {
      "label": "Span 2 length",
      "value": "82'-0\"",
      "unit": "ft-in",
      "appliesTo": "Bent 2 to Bent 3"
    },
    {
      "label": "Span 3 length",
      "value": "55'-0\"",
      "unit": "ft-in",
      "appliesTo": "Bent 3 to Bent 4"
    },
    {
      "label": "Gutter to gutter width",
      "value": "40'-0\"",
      "unit": "ft-in",
      "appliesTo": "Roadway between Bent 1 and Bent 2 area"
    },
    {
      "label": "Out to out width",
      "value": "43'-7\"",
      "unit": "ft-in",
      "appliesTo": "Bridge cross-section"
    },
    {
      "label": "Deck edge to point of min vert clearance",
      "value": "1'-9 1/2\"",
      "unit": "ft-in",
      "appliesTo": "Point of Min. Vert. Clearance"
    },
    {
      "label": "Offset dimension",
      "value": "6'-0\"",
      "unit": "ft-in",
      "appliesTo": "multiple locations near Bent 2/3"
    },
    {
      "label": "Width dimension",
      "value": "34'-0\"",
      "unit": "ft-in",
      "appliesTo": "Between Bent 2L/2R and Bent 3L/3R area"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "deg-min-sec",
      "appliesTo": "Typical skew angle at bents/walls"
    },
    {
      "label": "Bearing",
      "value": "N 2°-23'-16.7\" E",
      "unit": "bearing",
      "appliesTo": "Future access road centerline"
    },
    {
      "label": "Bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "bearing",
      "appliesTo": "SR 21 centerline"
    },
    {
      "label": "Distance",
      "value": "75'-10 5/16\"",
      "unit": "ft-in",
      "appliesTo": "Future track centerline dimension"
    },
    {
      "label": "Distance",
      "value": "74'-7 15/16\"",
      "unit": "ft-in",
      "appliesTo": "Existing railroad centerline dimension"
    },
    {
      "label": "Minimum clearance",
      "value": "12'-1\"",
      "unit": "ft-in",
      "appliesTo": "Central of Georgia Railroad existing track"
    },
    {
      "label": "Minimum clearance",
      "value": "14'-1\"",
      "unit": "ft-in",
      "appliesTo": "Future point of min vert clearance, right bridge"
    },
    {
      "label": "Station",
      "value": "STA. 17+23.00",
      "unit": "station",
      "appliesTo": "Begin Bridge"
    },
    {
      "label": "Station",
      "value": "STA. 17+29.07",
      "unit": "station",
      "appliesTo": "unspecified point"
    },
    {
      "label": "Station",
      "value": "STA. 18+16.85",
      "unit": "station",
      "appliesTo": "SR 21 centerline = Central of Georgia RR Sta. 303+80.83"
    },
    {
      "label": "Station",
      "value": "STA. 303+80.83",
      "unit": "station",
      "appliesTo": "Central of Georgia Railroad Company centerline"
    },
    {
      "label": "Station",
      "value": "STA. 19+08.93",
      "unit": "station",
      "appliesTo": "PT#3"
    },
    {
      "label": "Station",
      "value": "STA. 19+15.00",
      "unit": "station",
      "appliesTo": "End Bridge"
    },
    {
      "label": "RRMP",
      "value": "D-0080.54",
      "unit": "",
      "appliesTo": "Railroad milepost marker"
    },
    {
      "label": "Grade",
      "value": "+5.4180%",
      "unit": "%",
      "appliesTo": "Proposed vertical, SR 21 PGL (westbound, partial label '560' cut off)"
    },
    {
      "label": "Grade",
      "value": "+5.4443%",
      "unit": "%",
      "appliesTo": "Proposed vertical, SR 21 PGL (eastbound, partial label '560' cut off)"
    },
    {
      "label": "Min. Horiz. Clearance",
      "value": "36'-4\"",
      "unit": "ft-in",
      "appliesTo": "Calculated to face of column, west side"
    },
    {
      "label": "Min. Horiz. Clearance",
      "value": "25'-8\"",
      "unit": "ft-in",
      "appliesTo": "Calculated to face of column, east side"
    },
    {
      "label": "Offset dimension",
      "value": "15'-0\"",
      "unit": "ft-in",
      "appliesTo": "Two segments near Min. Horiz. Cl. callouts"
    },
    {
      "label": "Offset dimension",
      "value": "22'-0\"",
      "unit": "ft-in",
      "appliesTo": "Near PT#3 / end bridge area"
    }
  ],
  "notes": [
    "FRONT FACE OF WALL 1",
    "FRONT FACE OF WALL 2",
    "ℂ FUTURE ACCESS ROAD",
    "ℂ FUTURE TRACK",
    "ℂ CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK",
    "12'-1\" MIN.",
    "POINT OF MIN. VERT. CLEARANCE",
    "FUTURE POINT OF MIN. VERT. CLEARANCE",
    "AHEAD",
    "TO PERKINS",
    "TO US 25/SR 121",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "ℂ BENT 2L / ℂ BENT 2R",
    "ℂ BENT 3L / ℂ BENT 3R",
    "B.F.P.R. BENT 1L / 1R / 4L / 4R",
    "81°-20'-05.0\", TYP.",
    "STA. 18+16.85, ℂ SR 21 = STA. 303+80.83, ℂ CENTRAL OF GEORGIA RAILROAD COMPANY",
    "BEGIN BRIDGE STA. 17+23.00",
    "STA. 17+29.07",
    "RRMP D-0080.54",
    "ℂ SR 21",
    "N 83°-43'-21.7\" E",
    "PT#3",
    "END BRIDGE STA. 19+15.00",
    "TEMPORARY SHORING AS NECESSARY, TYP.",
    "TO BE REMOVED",
    "TO GA HIGHWAY 23",
    "RR R/W",
    "TO MILLEN",
    "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN",
    "CHAIN LINK WIRE FENCE, TYP.",
    "TOTAL LENGTH OF BRIDGE = 192'-0\" ***"
  ],
  "labels": [
    "PLAN",
    "PROPOSED VER... (partial, likely PROPOSED VERTICAL PROFILE) SR 21 PG...",
    "BENT ELEVATION... (table title partial)",
    "LOCATION",
    "BENT NO.",
    "LEFT BRIDGE",
    "RIGHT BRIDGE",
    "BENT 1, BENT 2, BENT 3, BENT 4 (table rows)"
  ],
  "description": "This crop is a plan view of a skewed bridge crossing over an existing Central of Georgia Railroad track, with a future access road and future track also shown, near SR 21 and connections to US 25/SR 121 and GA Highway 23. It details bent centerlines (Bents 1-4, left/right), wall faces, station and bearing data, minimum vertical/horizontal clearance callouts, and skew angles, plus a partial bent elevation table and beginning of a bridge elevation view along the bottom edge showing overall span lengths (55'-82'-55') and a chain link fence callout."
}

p01_r01 planPlan

  • WallWALL 1×2rectangular/retaining wall faceunspecified (likely reinforced concrete)Front face of Wall 1 shown at both approaches; one wall noted 'TO BE REMOVED'
  • WallWALL 2×2rectangular/retaining wall faceunspecifiedFront face of Wall 2 shown at both far ends

192'-0" ft-in Total length of bridge55'-0" ft-in Span 1 length82'-0" ft-in Span 2 length55'-0" ft-in Span 3 length40'-0" ft-in Gutter to gutter width43'-7" ft-in Out to out width1'-9 1/2" ft-in Deck edge to point of min vert clearance6'-0" ft-in Offset dimension+21 more

crop

p01_r07 plan

page 1 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p01_r07_plan
Original
p01_r07 plan
{
  "view": "Elevation",
  "objects": [
    {
      "name": "bridge superstructure",
      "tag": "",
      "shape": "continuous horizontal deck/girder profile",
      "material": "",
      "count": 1,
      "note": "Three-span bridge shown in elevation."
    },
    {
      "name": "bent",
      "tag": "B.F.P.R. BENT 1",
      "shape": "vertical end support",
      "material": "",
      "count": 1,
      "note": "Located at left bridge end; adjacent callout identifies FRONT FACE OF WALL NO. 1."
    },
    {
      "name": "bent",
      "tag": "BENT 2",
      "shape": "rectangular column with rectangular cap and pile-supported footing",
      "material": "",
      "count": 1,
      "note": "Interior bent with two visible vertical columns and four visible piles."
    },
    {
      "name": "bent",
      "tag": "BENT 3",
      "shape": "rectangular column with rectangular cap and pile-supported footing",
      "material": "",
      "count": 1,
      "note": "Interior bent with two visible vertical columns and four visible piles."
    },
    {
      "name": "bent",
      "tag": "B.F.P.R. BENT 4",
      "shape": "vertical end support",
      "material": "",
      "count": 1,
      "note": "Located at right bridge end; adjacent callout identifies FRONT FACE OF WALL NO. 2."
    },
    {
      "name": "wall",
      "tag": "WALL NO. 1",
      "shape": "vertical rectangular wall face",
      "material": "",
      "count": 1,
      "note": "Only the front face is indicated."
    },
    {
      "name": "wall",
      "tag": "WALL NO. 2",
      "shape": "vertical rectangular wall face",
      "material": "",
      "count": 1,
      "note": "Only the front face is indicated."
    },
    {
      "name": "bearing",
      "tag": "EXP.",
      "shape": "bearing symbol",
      "material": "",
      "count": 4,
      "note": "Four visible locations labeled EXP."
    },
    {
      "name": "bearing",
      "tag": "FIX",
      "shape": "bearing symbol",
      "material": "",
      "count": 2,
      "note": "Two visible locations labeled FIX."
    },
    {
      "name": "chain link wire fence",
      "tag": "",
      "shape": "fence panels",
      "material": "chain link wire",
      "count": 3,
      "note": "Shown along the bridge deck; labeled TYP."
    },
    {
      "name": "pile",
      "tag": "",
      "shape": "vertical slender pile",
      "material": "",
      "count": 8,
      "note": "Four visible below each of BENT 2 and BENT 3 footings."
    },
    {
      "name": "existing track",
      "tag": "",
      "shape": "vertical dashed alignment lines",
      "material": "",
      "count": 1,
      "note": "Center alignment is shown beneath the bridge."
    },
    {
      "name": "future track",
      "tag": "",
      "shape": "vertical dashed alignment lines",
      "material": "",
      "count": 1,
      "note": "Shown to the right of the existing track."
    }
  ],
  "measurements": [
    {
      "label": "TOTAL LENGTH OF BRIDGE",
      "value": "192’-0” ***",
      "unit": "ft-in",
      "appliesTo": "bridge superstructure"
    },
    {
      "label": "span length",
      "value": "55’-0” ***",
      "unit": "ft-in",
      "appliesTo": "B.F.P.R. BENT 1 to BENT 2"
    },
    {
      "label": "span length",
      "value": "82’-0” ***",
      "unit": "ft-in",
      "appliesTo": "BENT 2 to BENT 3"
    },
    {
      "label": "span length",
      "value": "55’-0” ***",
      "unit": "ft-in",
      "appliesTo": "BENT 3 to B.F.P.R. BENT 4"
    },
    {
      "label": "elevation",
      "value": "151.00",
      "unit": "",
      "appliesTo": "future groundline"
    }
  ],
  "notes": [
    "CHAIN LINK WIRE FENCE, TYP.",
    "FRONT FACE OF WALL NO. 1",
    "FRONT FACE OF WALL NO. 2",
    "EL. 151.00, TYP.",
    "APPROXIMATE EXISTING GROUNDLINE",
    "FUTURE GROUNDLINE"
  ],
  "labels": [
    "PLAN",
    "PGL",
    "℄ FUTURE ACCESS ROAD",
    "℄ EXISTING TRACK",
    "℄ FUTURE TRACK"
  ],
  "description": "This crop shows an elevation of a three-span bridge, with end bents at B.F.P.R. BENT 1 and B.F.P.R. BENT 4 and interior pile-supported BENT 2 and BENT 3. It documents the bridge length and span dimensions, deck-mounted chain link wire fence, bearing designations, wall-face callouts, and existing/future track and groundline references."
}

p01_r07 planElevation

  • wallWALL NO. 1×1vertical rectangular wall faceOnly the front face is indicated.
  • wallWALL NO. 2×1vertical rectangular wall faceOnly the front face is indicated.

192’-0” *** ft-in TOTAL LENGTH OF BRIDGE55’-0” *** ft-in span length82’-0” *** ft-in span length55’-0” *** ft-in span length151.00 elevation

crop

p01_r01

page 1 · other_p01_r01
Original
p01_r01
{
  "view": "Plan",
  "objects": [
    {
      "name": "Bridge deck / superstructure outline",
      "tag": "LEFT BRIDGE",
      "shape": "rectangular, skewed ends",
      "material": "",
      "count": 1,
      "note": "Upper bridge shown in plan between Walls 1 and 2."
    },
    {
      "name": "Bridge deck / superstructure outline",
      "tag": "RIGHT BRIDGE",
      "shape": "rectangular, skewed ends",
      "material": "",
      "count": 1,
      "note": "Lower bridge shown in plan between Walls 1 and 2."
    },
    {
      "name": "Wall",
      "tag": "WALL 1",
      "shape": "skewed rectangular wall line",
      "material": "",
      "count": 2,
      "note": "Front face called out at the left end of each bridge."
    },
    {
      "name": "Wall",
      "tag": "WALL 2",
      "shape": "skewed rectangular wall line",
      "material": "",
      "count": 2,
      "note": "Front face called out at the right end of each bridge."
    },
    {
      "name": "Bent",
      "tag": "BENT 1L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 2L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 3L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 4L",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 1R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 2R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 3R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Bent",
      "tag": "BENT 4R",
      "shape": "line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Gutter",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Gutter limits are dimensioned on both bridge plans."
    },
    {
      "name": "Central of Georgia Railroad Company existing track",
      "tag": "",
      "shape": "parallel linear tracks",
      "material": "",
      "count": null,
      "note": "Crosses beneath the bridge plans."
    },
    {
      "name": "Future access road",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Temporary shoring",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Shown near the railroad at the right side."
    },
    {
      "name": "Chain link wire fence",
      "tag": "",
      "shape": "fence line",
      "material": "chain link wire",
      "count": null,
      "note": "Only a partial lower-plan depiction is visible."
    }
  ],
  "measurements": [
    {
      "label": "Minimum dimension",
      "value": "12'-1\" MIN.",
      "unit": "",
      "appliesTo": "Central of Georgia Railroad Company existing track / future access road area"
    },
    {
      "label": "Dimension",
      "value": "74'-7 15/16\"",
      "unit": "",
      "appliesTo": "Upper bridge plan"
    },
    {
      "label": "Bearing / direction",
      "value": "N 2°-23'-16.71\" E",
      "unit": "",
      "appliesTo": "Upper bridge plan"
    },
    {
      "label": "Dimension",
      "value": "75'-10 15/16\"",
      "unit": "",
      "appliesTo": "Upper bridge plan"
    },
    {
      "label": "Minimum vertical clearance offset",
      "value": "1'-9½\"",
      "unit": "",
      "appliesTo": "Point of min. vert. clearance"
    },
    {
      "label": "Dimension",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "Point of min. vert. clearance"
    },
    {
      "label": "Gutter-to-gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "Upper bridge"
    },
    {
      "label": "Gutter-to-out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "Upper bridge"
    },
    {
      "label": "Width",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "Upper bridge"
    },
    {
      "label": "Skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "Walls / bridge ends"
    },
    {
      "label": "Station",
      "value": "STA. 18+16.85",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "Station",
      "value": "STA. 303+80.83",
      "unit": "",
      "appliesTo": "℄ Central of Georgia Railroad Company"
    },
    {
      "label": "Begin bridge station",
      "value": "STA. 17+23.00",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Station",
      "value": "STA. 17+29.07",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Bearing / direction",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "Station",
      "value": "STA. 19+08.93",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "End bridge station",
      "value": "STA. 19+15.00",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Width",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Minimum dimension",
      "value": "14'-1\" MIN.",
      "unit": "",
      "appliesTo": "Lower bridge / future point of min. vert. clearance"
    },
    {
      "label": "Gutter-to-gutter width",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Gutter-to-out width",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Width",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge"
    },
    {
      "label": "Dimension",
      "value": "15'-0\"",
      "unit": "",
      "appliesTo": "Lower bridge clearance area"
    },
    {
      "label": "Minimum horizontal clearance",
      "value": "25'-8\"",
      "unit": "",
      "appliesTo": "Face of column"
    },
    {
      "label": "Minimum horizontal clearance",
      "value": "36'-4\"",
      "unit": "",
      "appliesTo": "Face of column"
    },
    {
      "label": "Total length of bridge",
      "value": "192'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "82'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Proposed vertical grade",
      "value": "+5.4180%",
      "unit": "",
      "appliesTo": "SR 21 PGL"
    },
    {
      "label": "Proposed vertical grade",
      "value": "+5.4443%",
      "unit": "",
      "appliesTo": "SR 21 PGL"
    }
  ],
  "notes": [
    "POINT OF MIN. VERT. CLEARANCE",
    "FUTURE POINT OF MIN. VERT. CLEARANCE",
    "TEMPORARY SHORING AS NECESSARY, TYP.",
    "TO BE REMOVED",
    "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN",
    "CHAIN LINK WIRE FENCE, TYP."
  ],
  "labels": [
    "℄ FUTURE ACCESS ROAD",
    "℄ CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK",
    "TO PERKINS",
    "TO US 25/SR 121",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "℄ SR 21",
    "TO GA HIGHWAY 23",
    "RR R/W",
    "TO MILLEN",
    "PT #3",
    "RRMP D-0080.54",
    "PLAN",
    "BENT ELEVATIONS",
    "LOCATION",
    "BENT NO.",
    "LEFT BRIDGE",
    "RIGHT BRIDGE",
    "PROPOSED VERT",
    "SR 21 PGL",
    "N."
  ],
  "description": "This crop is a plan view of two parallel bridge structures carrying SR 21 across the Central of Georgia Railroad Company existing track. It shows the left- and right-bridge bent locations, wall front faces, gutters, roadway centerlines, clearance callouts, railroad/right-of-way features, and partial bridge-length dimensions. A partial bent-elevations table and portions of proposed vertical-profile graphics are visible at the right and lower edges."
}

p01_r01Plan

  • WallWALL 1×2skewed rectangular wall lineFront face called out at the left end of each bridge.
  • WallWALL 2×2skewed rectangular wall lineFront face called out at the right end of each bridge.

12'-1" MIN. Minimum dimension74'-7 15/16" DimensionN 2°-23'-16.71" E Bearing / direction75'-10 15/16" Dimension1'-9½" Minimum vertical clearance offset6'-0" Dimension40'-0" Gutter-to-gutter width43'-7" Gutter-to-out width+23 more

Page 13

crop

p13_r05 2 0 min

page 13 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p13_r05_2_0_min
Original
p13_r05 2 0 min
{
  "view": "Detail",
  "objects": [
    {
      "name": "cap",
      "tag": "CAP",
      "shape": "rectangular with chamfered corners",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "vertical support members",
      "tag": "",
      "shape": "paired parallel-line vertical members",
      "material": "",
      "count": 2,
      "note": "Extend below crop with break symbols."
    },
    {
      "name": "connecting element",
      "tag": "",
      "shape": "tapered and offset parallel-line profile",
      "material": "",
      "count": 1,
      "note": "Connects the cap area to the wall area; identity is not labeled in the visible crop."
    },
    {
      "name": "wall",
      "tag": "",
      "shape": "rectangular vertical wall/profile",
      "material": "",
      "count": 1,
      "note": "Callout identifies the visible face as partial text: \"FRONT OF WA\"."
    },
    {
      "name": "rectangular block at wall",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Adjacent to the wall; callout text at right is cropped and reads only \"C\"."
    }
  ],
  "measurements": [
    {
      "label": "minimum horizontal distance from B.F.P.R. reference to wall reference",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal cap dimension",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "CAP"
    },
    {
      "label": "minimum vertical cap dimension",
      "value": "2'-0\"",
      "unit": "",
      "appliesTo": "CAP"
    }
  ],
  "notes": [],
  "labels": [
    "B.F.P.R.",
    "C",
    "FRONT OF WA"
  ],
  "description": "This crop shows a detail of a labeled CAP supported by two vertical members, with a profiled connecting element leading toward a wall. The right-side wall callouts are cropped, and only partial text is visible."
}

p13_r05 2 0 minDetail

  • wall×1rectangular vertical wall/profileCallout identifies the visible face as partial text: "FRONT OF WA".

6'-0" minimum horizontal distance from B.F.P.R. reference to wall reference3'-0" horizontal cap dimension2'-0" minimum vertical cap dimension

crop

p13_r10 section at end bent and wall

page 13 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p13_r10_section_at_end_bent_and_wall
Original
p13_r10 section at end bent and wall
{
  "view": "Section",
  "objects": [
    {
      "name": "wall",
      "tag": "",
      "shape": "partial rectangular",
      "material": "",
      "count": null,
      "note": "Only a partial edge/profile of the wall is visible in this crop."
    }
  ],
  "measurements": [
    {
      "label": "SCALE",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "SECTION AT END BENT AND WALL"
    }
  ],
  "notes": [
    "FRONT OF WALL"
  ],
  "labels": [
    "SECTION AT END BENT AND WALL"
  ],
  "description": "This crop shows the title and scale for a section at an end bent and wall. A partial wall profile is visible at the upper right, with a callout identifying the front of wall."
}

p13_r10 section at end bent and wallSection

  • wallpartial rectangularOnly a partial edge/profile of the wall is visible in this crop.

3/4" = 1'-0" SCALE

crop

p13_r05

page 13 · other_p13_r05
Original
p13_r05
{
  "view": "Section",
  "objects": [
    {
      "name": "cap",
      "tag": "",
      "shape": "rectangular with chamfered corners",
      "material": "",
      "count": 1,
      "note": "Labeled \"CAP\"."
    },
    {
      "name": "piles",
      "tag": "",
      "shape": "parallel-line vertical members",
      "material": "",
      "count": 2,
      "note": "Extend below cap; lower portions are cut off by the crop."
    },
    {
      "name": "wall",
      "tag": "",
      "shape": "rectangular vertical wall",
      "material": "",
      "count": 1,
      "note": "Shown at right; lower portion is cut off by the crop."
    }
  ],
  "measurements": [
    {
      "label": "minimum horizontal dimension",
      "value": "6'-0\" MIN.",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal dimension",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "cap"
    },
    {
      "label": "minimum vertical dimension",
      "value": "2'-0\" MIN.",
      "unit": "",
      "appliesTo": "cap"
    }
  ],
  "notes": [],
  "labels": [
    "B.F.P.R.",
    "CAP",
    "CON... (partial)",
    "FRONT OF WAL... (partial)",
    "SECTION AT END BENT AND WALL"
  ],
  "description": "This crop shows a section at an end bent and wall. A capped pair of vertical pile members is shown at left, with a connecting profile extending toward a vertical wall at right; portions of the wall and pile lengths are outside the crop."
}

p13_r05Section

  • wall×1rectangular vertical wallShown at right; lower portion is cut off by the crop.

6'-0" MIN. minimum horizontal dimension3'-0" horizontal dimension2'-0" MIN. minimum vertical dimension

crop

p13_r10

page 13 · other_p13_r10
Original
p13_r10
{
  "view": "Section",
  "objects": [
    {
      "name": "wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": 1,
      "note": "Only a partial wall outline is visible; callout text is cut off."
    }
  ],
  "measurements": [
    {
      "label": "SCALE",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "Section at End Bent and Wall"
    }
  ],
  "notes": [
    "FRONT FA... OF WALL (partial)"
  ],
  "labels": [
    "SECTION AT END BENT AND WALL"
  ],
  "description": "This crop shows the title and scale for a section view at an end bent and wall. A small partial wall section is visible at the upper right with a partially cropped front-face callout."
}

p13_r10Section

  • wall×1Only a partial wall outline is visible; callout text is cut off.

3/4" = 1'-0" SCALE

Page 17

crop

p17_r05 2 0 min

page 17 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p17_r05_2_0_min
Original
p17_r05 2 0 min
{
  "view": "Detail",
  "objects": [
    {
      "name": "cap",
      "tag": "CAP",
      "shape": "rectangular with chamfered corners",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "vertical support members",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Shown extending below the cap; lower portions are broken off."
    },
    {
      "name": "connecting member",
      "tag": "",
      "shape": "stepped/tapered profile",
      "material": "",
      "count": 1,
      "note": "Connects the cap area to the wall area."
    },
    {
      "name": "wall",
      "tag": "",
      "shape": "rectangular vertical stem with rectangular block at upper portion",
      "material": "",
      "count": 1,
      "note": "Callout identifies the front of wall; text is cropped."
    }
  ],
  "measurements": [
    {
      "label": "minimum horizontal distance from B.F.P.R. to wall reference line",
      "value": "6'-0\" MIN.",
      "unit": "",
      "appliesTo": "wall"
    },
    {
      "label": "horizontal cap dimension",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "CAP"
    },
    {
      "label": "minimum vertical cap dimension",
      "value": "2'-0\" MIN.",
      "unit": "",
      "appliesTo": "CAP"
    }
  ],
  "notes": [],
  "labels": [
    "B.F.P.R.",
    "C... (partial)",
    "FRONT OF WA... (partial)"
  ],
  "description": "This crop shows a structural detail with a rectangular CAP supported by two vertical members and connected by a stepped profile to a wall element. The crop documents minimum cap dimensions and a 6-foot minimum horizontal relationship from the B.F.P.R. reference to the wall reference line."
}

p17_r05 2 0 minDetail

  • wall×1rectangular vertical stem with rectangular block at upper portionCallout identifies the front of wall; text is cropped.

6'-0" MIN. minimum horizontal distance from B.F.P.R. to wall reference line3'-0" horizontal cap dimension2'-0" MIN. minimum vertical cap dimension

crop

p17_r10 section at end bent and wall

page 17 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p17_r10_section_at_end_bent_and_wall
Original
p17_r10 section at end bent and wall
{
  "view": "Section",
  "objects": [
    {
      "name": "wall",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Only a partial vertical wall element is visible at the upper right."
    }
  ],
  "measurements": [
    {
      "label": "Scale",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "SECTION AT END BENT AND WALL"
    }
  ],
  "notes": [],
  "labels": [
    "SECTION AT END BENT AND WALL",
    "SCALE: 3/4\" = 1'-0\"",
    "FRONT OF WALL (partial)"
  ],
  "description": "This crop contains the title and scale for a section view at an end bent and wall. Only a small partial portion of the wall section and its callout are visible; no end-bent geometry is shown in this crop."
}

p17_r10 section at end bent and wallSection

  • wallOnly a partial vertical wall element is visible at the upper right.

3/4" = 1'-0" Scale

crop

p17_r05

page 17 · other_p17_r05
Original
p17_r05
{
  "view": "Section",
  "objects": [
    {
      "name": "cap",
      "tag": "",
      "shape": "rectangular with chamfered corners",
      "material": "",
      "count": 1,
      "note": "Labeled CAP."
    },
    {
      "name": "pile",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Two vertical pile elements are shown below the cap; lower portions are broken off."
    },
    {
      "name": "wall",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Wall is partially shown at right; callout reads partial \"FRONT OF WAL\"."
    }
  ],
  "measurements": [
    {
      "label": "minimum horizontal dimension from B.F.P.R. reference",
      "value": "6'-0\" MIN.",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "horizontal cap dimension",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "cap"
    },
    {
      "label": "minimum vertical cap dimension",
      "value": "2'-0\" MIN.",
      "unit": "",
      "appliesTo": "cap"
    }
  ],
  "notes": [],
  "labels": [
    "B.F.P.R.",
    "CAP",
    "CON",
    "FRONT OF WAL",
    "SECTION AT END BENT AND WALL"
  ],
  "description": "This crop shows a partial section at an end bent and wall. A cap supported by two piles is shown at left, with a partially visible wall and intervening sloping profile at right; the full right-side callouts and lower portions are cropped."
}

p17_r05Section

  • wall×1rectangularWall is partially shown at right; callout reads partial "FRONT OF WAL".

6'-0" MIN. minimum horizontal dimension from B.F.P.R. reference3'-0" horizontal cap dimension2'-0" MIN. minimum vertical cap dimension

crop

p17_r10

page 17 · other_p17_r10
Original
p17_r10
{
  "view": "Section",
  "objects": [
    {
      "name": "wall",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Only a partial wall is visible."
    }
  ],
  "measurements": [
    {
      "label": "SCALE",
      "value": "3/4\" = 1'-0\"",
      "unit": "",
      "appliesTo": "SECTION AT END BENT AND WALL"
    }
  ],
  "notes": [
    "FRONT FACE OF WALL"
  ],
  "labels": [
    "SECTION AT END BENT AND WALL"
  ],
  "description": "This crop shows the title and scale for a section at an end bent and wall. A partial vertical wall element is visible with a callout identifying its front face."
}

p17_r10Section

  • wall×1rectangularOnly a partial wall is visible.

3/4" = 1'-0" SCALE