Drawing → BOQ
← Mindmapwhat the drawings said

Waterproofing

1 page · 2 crops · ×1 · deck

Matched toDeck Waterproofingbridge.superstructure.deck_system.waterproofingon “Waterproofing

1 read off the drawings · 3 not established
The class asks forValueHowFrom
LengthLwants m/mmnot establishedThe section identifies waterproofing but gives no dimension or extents for the waterproofing layer. The shown dimensions apply to the endwall, beam, reinforcement, or joint filler, not explicitly to waterproofing.not found
WidthWwants m/mmnot establishedNo width dimension or bounded transverse extent is stated for waterproofing. Dimensions shown are assigned to other items.not found
Surface AreaA_surfacewants m2not establishedWaterproofing surface area cannot be derived because neither its length nor width/coverage extents are established in the provided section readings.not found
Material TypeMATWaterproofing, see Section 530 of the Georgia DOT Specifications -The waterproofing callout expressly directs that the material comply with Section 530 of the Georgia DOT Specifications; no more specific product or material composition is stated.readp8 · p08_r03 section at endwallp8 · p08_r03

Worked out by openai/gpt-5.6-terra-pro from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

Every dimension read for it1

  • 3/4″ = 1′-0″scalenot attributedp8 · p08_r03 section at endwall

Notes on the sheets that carry it

  • p8506B AT 18″ ±, ALT. TO GIVE 9″ SP.
  • p83 1/2″ MIN. CL.
  • p82″ CL. 3 SIDES
  • p88-504B AT 12″ ± BETWEEN BEAMS
  • p82-504A AT END OF BEAM
  • p8BEARING PAD NOT SHOWN
  • p81/2″ PREFORMED JOINT FILLER
  • p8WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS
  • p8SLAB REINFORCEMENT NOT SHOWN
  • p8END BENT 1 SHOWN
  • p8END BENT 4 SIMILAR
  • p8506A AT 18”

Every crop it was read in — the drawing beside what the model took off it

Page 8

crop

p08_r03 section at endwall

page 8 · gdot_drawing_83a3db2262b94086918a1e232d2b9607_p08_r03_section_at_endwall
Original
p08_r03 section at endwall
{
  "view": "Section",
  "objects": [
    {
      "name": "endwall",
      "tag": "",
      "shape": "stepped vertical wall with tapered haunch",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Sectioned endwall at beam ends."
    },
    {
      "name": "beam ends",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 3,
      "note": "Only portions of beam ends are visible in this crop."
    },
    {
      "name": "reinforcement bar",
      "tag": "506B",
      "shape": "bent",
      "material": "reinforcing steel",
      "count": null,
      "note": "At 18 in. ±, alternating to provide 9 in. spacing."
    },
    {
      "name": "reinforcement bar",
      "tag": "506A",
      "shape": "bent",
      "material": "reinforcing steel",
      "count": null,
      "note": "At 18 in."
    },
    {
      "name": "reinforcement bar",
      "tag": "900",
      "shape": "straight",
      "material": "reinforcing steel",
      "count": 4,
      "note": ""
    },
    {
      "name": "reinforcement bar",
      "tag": "504B",
      "shape": "straight",
      "material": "reinforcing steel",
      "count": 8,
      "note": "Between beams."
    },
    {
      "name": "reinforcement bar",
      "tag": "504A",
      "shape": "straight",
      "material": "reinforcing steel",
      "count": 2,
      "note": "At end of beam."
    },
    {
      "name": "reinforcement bar",
      "tag": "401",
      "shape": "bent",
      "material": "reinforcing steel",
      "count": 4,
      "note": ""
    },
    {
      "name": "reinforcement bar",
      "tag": "505",
      "shape": "bent",
      "material": "reinforcing steel",
      "count": 1,
      "note": ""
    },
    {
      "name": "preformed joint filler",
      "tag": "",
      "shape": "horizontal strip",
      "material": "",
      "count": 1,
      "note": "Located between the endwall and bearing support."
    },
    {
      "name": "waterproofing",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "See Section 530 of the Georgia DOT Specifications."
    }
  ],
  "measurements": [
    {
      "label": "horizontal dimension",
      "value": "12″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "horizontal dimension",
      "value": "1′-6″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "horizontal dimension",
      "value": "8″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "radius",
      "value": "1/4″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "reinforcement spacing",
      "value": "18″ ±",
      "unit": "",
      "appliesTo": "506B"
    },
    {
      "label": "alternate reinforcement spacing",
      "value": "9″",
      "unit": "",
      "appliesTo": "506B"
    },
    {
      "label": "minimum clear cover",
      "value": "3 1/2″",
      "unit": "",
      "appliesTo": "506B"
    },
    {
      "label": "reinforcement spacing",
      "value": "18″",
      "unit": "",
      "appliesTo": "506A"
    },
    {
      "label": "vertical dimension",
      "value": "10″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "9″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "12″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "clear cover",
      "value": "2″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "reinforcement count",
      "value": "4-900",
      "unit": "",
      "appliesTo": "900"
    },
    {
      "label": "vertical dimension",
      "value": "8″",
      "unit": "",
      "appliesTo": "beam ends"
    },
    {
      "label": "reinforcement spacing",
      "value": "12″ ±",
      "unit": "",
      "appliesTo": "504B"
    },
    {
      "label": "reinforcement count",
      "value": "8-504B",
      "unit": "",
      "appliesTo": "504B"
    },
    {
      "label": "reinforcement count",
      "value": "2-504A",
      "unit": "",
      "appliesTo": "504A"
    },
    {
      "label": "reinforcement count",
      "value": "4-401",
      "unit": "",
      "appliesTo": "401"
    },
    {
      "label": "vertical dimension",
      "value": "1′-0″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "1′-0″",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "joint filler thickness",
      "value": "1/2″",
      "unit": "",
      "appliesTo": "preformed joint filler"
    },
    {
      "label": "scale",
      "value": "3/4″ = 1′-0″",
      "unit": "",
      "appliesTo": ""
    }
  ],
  "notes": [
    "506B AT 18″ ±, ALT. TO GIVE 9″ SP.",
    "3 1/2″ MIN. CL.",
    "2″ CL. 3 SIDES",
    "8-504B AT 12″ ± BETWEEN BEAMS",
    "2-504A AT END OF BEAM",
    "BEARING PAD NOT SHOWN",
    "1/2″ PREFORMED JOINT FILLER",
    "WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS",
    "SLAB REINFORCEMENT NOT SHOWN",
    "END BENT 1 SHOWN",
    "END BENT 4 SIMILAR"
  ],
  "labels": [
    "SECTION AT ENDWALL",
    "SCALE: 3/4″ = 1′-0″"
  ],
  "description": "This crop is a section at an endwall, showing the reinforced concrete endwall profile adjacent to beam ends. It documents endwall reinforcement, beam-end reinforcement callouts, clear cover, waterproofing, and the preformed joint filler; bearing pad and slab reinforcement are specifically noted as not shown."
}

p08_r03 section at endwallSection

  • waterproofingSee Section 530 of the Georgia DOT Specifications.

12″ horizontal dimension1′-6″ horizontal dimension8″ horizontal dimension1/4″ radius18″ ± reinforcement spacing9″ alternate reinforcement spacing3 1/2″ minimum clear cover18″ reinforcement spacing+14 more

crop

p08_r03

page 8 · other_p08_r03
Original
p08_r03
{
  "view": "Section",
  "objects": [
    {
      "name": "endwall",
      "tag": "",
      "shape": "stepped and tapered section",
      "material": "",
      "count": 1,
      "note": "Sectioned at endwall."
    },
    {
      "name": "beam",
      "tag": "",
      "shape": "rectangular",
      "material": "",
      "count": 1,
      "note": "Partial beam end is shown at right."
    },
    {
      "name": "reinforcement bar",
      "tag": "505",
      "shape": "bent",
      "material": "steel",
      "count": 1,
      "note": "Called out as 1-505."
    },
    {
      "name": "reinforcement bar",
      "tag": "506B",
      "shape": "bent",
      "material": "steel",
      "count": null,
      "note": "Alternate spacing is called out."
    },
    {
      "name": "reinforcement bar",
      "tag": "506A",
      "shape": "bent",
      "material": "steel",
      "count": null,
      "note": ""
    },
    {
      "name": "reinforcement bar",
      "tag": "900",
      "shape": "bent",
      "material": "steel",
      "count": 4,
      "note": ""
    },
    {
      "name": "reinforcement bar",
      "tag": "504B",
      "shape": "bent",
      "material": "steel",
      "count": 8,
      "note": "Between beams."
    },
    {
      "name": "reinforcement bar",
      "tag": "504A",
      "shape": "bent",
      "material": "steel",
      "count": 2,
      "note": "At end of beam."
    },
    {
      "name": "reinforcement bar",
      "tag": "401",
      "shape": "bent",
      "material": "steel",
      "count": 4,
      "note": ""
    },
    {
      "name": "preformed joint filler",
      "tag": "",
      "shape": "strip",
      "material": "",
      "count": 1,
      "note": "Located at the endwall/slab joint."
    },
    {
      "name": "waterproofing",
      "tag": "",
      "shape": "layer",
      "material": "",
      "count": 1,
      "note": "Applied at the exterior face indicated."
    }
  ],
  "measurements": [
    {
      "label": "horizontal dimension",
      "value": "12”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "horizontal dimension",
      "value": "1’-6”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "horizontal dimension",
      "value": "8”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "radius",
      "value": "1/4”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "minimum clear cover",
      "value": "3½”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "10”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "9”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "12”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "clear cover, 3 sides",
      "value": "2”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "1’-0”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "1’-0”",
      "unit": "",
      "appliesTo": "endwall"
    },
    {
      "label": "vertical dimension",
      "value": "8”",
      "unit": "",
      "appliesTo": "beam"
    },
    {
      "label": "506B spacing",
      "value": "18” ±",
      "unit": "",
      "appliesTo": "506B"
    },
    {
      "label": "506B alternate spacing",
      "value": "9”",
      "unit": "",
      "appliesTo": "506B"
    },
    {
      "label": "506A spacing",
      "value": "18”",
      "unit": "",
      "appliesTo": "506A"
    },
    {
      "label": "504B spacing",
      "value": "12” ±",
      "unit": "",
      "appliesTo": "504B"
    },
    {
      "label": "joint filler thickness",
      "value": "1/2”",
      "unit": "",
      "appliesTo": "preformed joint filler"
    },
    {
      "label": "scale",
      "value": "3/4” = 1’-0”",
      "unit": "",
      "appliesTo": "SECTION AT ENDWALL"
    }
  ],
  "notes": [
    "506B AT 18” ±, ALT. TO GIVE 9” SP.",
    "506A AT 18”",
    "8-504B AT 12” ± BETWEEN BEAMS",
    "2-504A AT END OF BEAM",
    "BEARING PAD NOT SHOWN",
    "WATERPROOFING, SEE SECTION 530 OF THE GEORGIA DOT SPECIFICATIONS",
    "1/2” PREFORMED JOINT FILLER",
    "SLAB REINFORCEMENT NOT SHOWN"
  ],
  "labels": [
    "SECTION AT ENDWALL",
    "END BENT 1 SHOWN",
    "END BENT 4 SIMILAR",
    "SCALE: 3/4” = 1’-0”"
  ],
  "description": "This crop is a section at an endwall, showing the end of a beam bearing at the end bent and the adjacent slab/endwall profile. It documents reinforcing-bar callouts, clearances, waterproofing, joint filler, and notes for End Bent 1; End Bent 4 is noted as similar."
}

p08_r03Section

  • waterproofing×1layerApplied at the exterior face indicated.

12” horizontal dimension1’-6” horizontal dimension8” horizontal dimension1/4” radius3½” minimum clear cover10” vertical dimension9” vertical dimension12” vertical dimension+10 more