Drawing → BOQ
← Mindmapwhat the drawings said

Structural Member

1 page · 1 crop · superstructure

⚠ No class in the bridge ontology fits this itemAdd a class

The ontology would need a generic structural member class.

How the sheets named it

member400B400C

Every dimension read for it9

  • 82'-0"overall deck widthnot attributedp3 · p03_r01 deck plan
  • 16'-4½"deck-width segmentnot attributedp3 · p03_r01 deck plan
  • 16'-6"deck-width end segmentnot attributedp3 · p03_r01 deck plan
  • 2'-0"minimum lapp3 · p03_r01 deck plan
  • 5'-0"dimension at marked symbolsnot attributedp3 · p03_r01 deck plan
  • 1'-9½"deck edge dimensionnot attributedp3 · p03_r01 deck plan
  • 40'-0"gutter to gutternot attributedp3 · p03_r01 deck plan
  • 43'-7"out to outnot attributedp3 · p03_r01 deck plan
  • 81°-20'-05.0"typical anglenot attributedp3 · p03_r01 deck plan

Notes on the sheets that carry it

  • p38" FILLET, TYP.
  • p31'-0" EDGEBEAM, TYP.
  • p381°-20'-05.0", TYP.
  • p310" CONCRETE DIAPHRAGM, TYP.
  • p32'-0" MIN. LAP
  • p3FENCE POST SPACING

Every crop it was read in — the drawing beside what the model took off it

Page 3

crop

p03_r01 deck plan

page 3 · gdot_drawing_for_one_item_1d2aef44145e4a0fb4e1079a43f94de1_p03_r01_deck_plan
Original
p03_r01 deck plan
{
  "view": "Plan",
  "objects": [
    {
      "name": "deck slab",
      "tag": "",
      "shape": "tapered rectangular plan area",
      "material": "",
      "count": 2,
      "note": "Two deck-plan areas are shown, separated by the construction centerline."
    },
    {
      "name": "edge beam",
      "tag": "",
      "shape": "longitudinal tapered member",
      "material": "",
      "count": 4,
      "note": "Called out as 1'-0\" EDGEBEAM, TYP."
    },
    {
      "name": "beam",
      "tag": "C BEAM 1 through C BEAM 12",
      "shape": "longitudinal parallel members",
      "material": "",
      "count": 12,
      "note": "Beams 1 through 6 are visible in the upper deck area and Beams 7 through 12 in the lower deck area."
    },
    {
      "name": "concrete diaphragm",
      "tag": "",
      "shape": "transverse rectangular",
      "material": "concrete",
      "count": 2,
      "note": "Called out as 10\" CONCRETE DIAPHRAGM, TYP."
    },
    {
      "name": "fillet",
      "tag": "",
      "shape": "linear edge fillet",
      "material": "",
      "count": null,
      "note": "Called out as 8\" FILLET, TYP."
    },
    {
      "name": "fence",
      "tag": "12-502D",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Repeated fence callout along deck edges; fence post spacing is dimensioned."
    },
    {
      "name": "fence end section",
      "tag": "12-502E",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Occurs at the right-side end portions of the fence."
    },
    {
      "name": "member",
      "tag": "400B",
      "shape": "longitudinal",
      "material": "",
      "count": null,
      "note": "Tag points to a longitudinal member in each deck area."
    },
    {
      "name": "member",
      "tag": "400C",
      "shape": "longitudinal",
      "material": "",
      "count": null,
      "note": "Tag points to a longitudinal member in each deck area."
    }
  ],
  "measurements": [
    {
      "label": "overall deck width",
      "value": "82'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "deck-width segment",
      "value": "16'-4½\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "deck-width end segment",
      "value": "16'-6\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "fence post spacing",
      "value": "9'-6\"",
      "unit": "",
      "appliesTo": "12-502D"
    },
    {
      "label": "fence post spacing",
      "value": "9'-10½\"",
      "unit": "",
      "appliesTo": "12-502D"
    },
    {
      "label": "end offset",
      "value": "3'-0\"",
      "unit": "",
      "appliesTo": "fence"
    },
    {
      "label": "end offset",
      "value": "2'-0\"",
      "unit": "",
      "appliesTo": "fence"
    },
    {
      "label": "edgebeam width",
      "value": "1'-0\"",
      "unit": "",
      "appliesTo": "edge beam"
    },
    {
      "label": "fillet size",
      "value": "8\"",
      "unit": "",
      "appliesTo": "fillet"
    },
    {
      "label": "concrete diaphragm thickness",
      "value": "10\"",
      "unit": "",
      "appliesTo": "concrete diaphragm"
    },
    {
      "label": "minimum lap",
      "value": "2'-0\"",
      "unit": "",
      "appliesTo": "400C"
    },
    {
      "label": "dimension at marked symbols",
      "value": "5'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "deck edge dimension",
      "value": "1'-9½\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "gutter to gutter",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "out to out",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "dimension at PGL westbound",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "PGL WESTBOUND"
    },
    {
      "label": "dimension at PGL eastbound",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "PGL EASTBOUND"
    },
    {
      "label": "typical angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "construction centerline angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "CONSTRUCTION C SR 21"
    },
    {
      "label": "bearing",
      "value": "N 83°-43'-21.7\" E",
      "unit": "",
      "appliesTo": "CONSTRUCTION C SR 21"
    }
  ],
  "notes": [
    "8\" FILLET, TYP.",
    "1'-0\" EDGEBEAM, TYP.",
    "81°-20'-05.0\", TYP.",
    "10\" CONCRETE DIAPHRAGM, TYP.",
    "2'-0\" MIN. LAP",
    "FENCE POST SPACING"
  ],
  "labels": [
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "CONSTRUCTION C SR 21",
    "SPAN 2",
    "DECK PLAN"
  ],
  "description": "This crop is a deck plan for SPAN 2, showing two tapered deck areas and the bridge framing identified as C BEAM 1 through C BEAM 12. The plan documents deck width, beam layout, edge beams, diaphragms, fence-post spacing, gutter-to-gutter and out-to-out dimensions, and the westbound and eastbound PGL locations."
}

p03_r01 deck planPlan

  • member400BlongitudinalTag points to a longitudinal member in each deck area.
  • member400ClongitudinalTag points to a longitudinal member in each deck area.

82'-0" overall deck width16'-4½" deck-width segment16'-6" deck-width end segment9'-6" fence post spacing9'-10½" fence post spacing3'-0" end offset2'-0" end offset1'-0" edgebeam width+12 more