Drawing → BOQ
← Mindmapwhat the drawings said

Temporary Shoring

1 page · 1 crop · ancillary

Matched toExcavation Shoringbridge.construction_system.shoringon “Temporary Shoring

4 not established
The class asks forValueHowFrom
LengthLwants m/mmnot establishedTemporary shoring is identified only by the note “TEMPORARY SHORING AS NECESSARY, TYP.” No dimension is assigned to the temporary shoring extent. The stated bridge, track, clearance, and span dimensions do not establish the shoring length.not found
HeightHwants m/mmnot establishedThe plan identifies temporary shoring but provides no shoring height, elevation, or vertical dimension applicable to it.not found
Surface AreaA_surfacewants m2not establishedNo temporary-shoring length and height are stated or derivable; therefore its surface area cannot be calculated.not found
Material TypeMATnot establishedThe temporary-shoring callout does not state a material type.not found

Worked out by openai/gpt-5.6-terra from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

Notes on the sheets that carry it

  • p1POINT OF MIN. VERT. CLEARANCE
  • p1FUTURE POINT OF MIN. VERT. CLEARANCE
  • p1TEMPORARY SHORING AS NECESSARY, TYP.
  • p1TO BE REMOVED
  • p1MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN
  • p1CHAIN LINK WIRE FENCE, TYP.

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r01 plan

page 1 · gdot_drawing_for_one_item_1d2aef44145e4a0fb4e1079a43f94de1_p01_r01_plan
Original
p01_r01 plan
{
  "view": "Plan",
  "objects": [
    {
      "name": "bridge deck",
      "tag": "",
      "shape": "rectangular, skewed",
      "material": "",
      "count": 2,
      "note": "Parallel left and right bridge deck outlines are shown."
    },
    {
      "name": "bent",
      "tag": "BENT 1L / BENT 2L / BENT 3L / BENT 4L",
      "shape": "line",
      "material": "",
      "count": 4,
      "note": "Left bridge bent lines are identified in the plan."
    },
    {
      "name": "bent",
      "tag": "BENT 1R / BENT 2R / BENT 3R / BENT 4R",
      "shape": "line",
      "material": "",
      "count": 4,
      "note": "Right bridge bent lines are identified in the plan."
    },
    {
      "name": "wall",
      "tag": "WALL 1",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Front faces of Wall 1 are called out at the left ends of the two bridge outlines."
    },
    {
      "name": "wall",
      "tag": "WALL 2",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Front faces of Wall 2 are called out at the right ends of the two bridge outlines."
    },
    {
      "name": "gutter",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": 4,
      "note": "Gutter locations are identified at the bridge center-side edges."
    },
    {
      "name": "railroad track",
      "tag": "CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Existing track crosses through the bridge area."
    },
    {
      "name": "future track",
      "tag": "FUTURE TRACK",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Future track is shown near the upper bridge."
    },
    {
      "name": "future access road",
      "tag": "FUTURE ACCESS ROAD",
      "shape": "linear",
      "material": "",
      "count": 1,
      "note": "Callout points to a future access road."
    },
    {
      "name": "temporary shoring",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Shown along the railroad crossing area; identified as typical/as necessary."
    },
    {
      "name": "chain link wire fence",
      "tag": "",
      "shape": "linear",
      "material": "",
      "count": null,
      "note": "Only a partial fence callout and fragments are visible at the bottom of the crop."
    }
  ],
  "measurements": [
    {
      "label": "minimum dimension",
      "value": "12'-1\"",
      "unit": "",
      "appliesTo": "CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK / FUTURE ACCESS ROAD"
    },
    {
      "label": "dimension",
      "value": "74'-7 15/16\"",
      "unit": "",
      "appliesTo": "upper bridge plan"
    },
    {
      "label": "area dimension",
      "value": "N. 2'-23'-16'-7\"",
      "unit": "",
      "appliesTo": "AREA"
    },
    {
      "label": "dimension",
      "value": "75'-10 15/16\"",
      "unit": "",
      "appliesTo": "FUTURE TRACK"
    },
    {
      "label": "minimum vertical clearance",
      "value": "1'-9 1/2\"",
      "unit": "",
      "appliesTo": "upper bridge"
    },
    {
      "label": "gutter to gutter",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "upper bridge"
    },
    {
      "label": "gutter to gutter",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "upper bridge"
    },
    {
      "label": "spacing",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "upper bridge"
    },
    {
      "label": "dimension",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "upper bridge"
    },
    {
      "label": "skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "BENT 1L / BENT 4L"
    },
    {
      "label": "station",
      "value": "18+16.85",
      "unit": "",
      "appliesTo": "SR 21"
    },
    {
      "label": "station",
      "value": "303+80.83",
      "unit": "",
      "appliesTo": "CENTRAL OF GEORGIA RAILROAD COMPANY"
    },
    {
      "label": "station",
      "value": "17+23.00",
      "unit": "",
      "appliesTo": "BEGIN BRIDGE"
    },
    {
      "label": "station",
      "value": "17+29.07",
      "unit": "",
      "appliesTo": "railroad alignment"
    },
    {
      "label": "railroad milepost",
      "value": "D-0008.54",
      "unit": "",
      "appliesTo": "RRMP"
    },
    {
      "label": "minimum vertical clearance",
      "value": "1'-9 1/2\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "gutter to gutter",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "gutter to gutter",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "spacing",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "dimension",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "skew angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "BENT 1R / BENT 4R"
    },
    {
      "label": "dimension",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "station",
      "value": "19+08.93",
      "unit": "",
      "appliesTo": "SR 21"
    },
    {
      "label": "skew angle",
      "value": "83°-43'-21.7\"",
      "unit": "",
      "appliesTo": "SR 21"
    },
    {
      "label": "station",
      "value": "19+15.00",
      "unit": "",
      "appliesTo": "END BRIDGE"
    },
    {
      "label": "dimension",
      "value": "15'-0\"",
      "unit": "",
      "appliesTo": "lower bridge / future point of minimum vertical clearance"
    },
    {
      "label": "dimension",
      "value": "25'-8\"",
      "unit": "",
      "appliesTo": "minimum horizontal clearance to face of column"
    },
    {
      "label": "dimension",
      "value": "36'-4\"",
      "unit": "",
      "appliesTo": "minimum horizontal clearance to face of column"
    },
    {
      "label": "minimum dimension",
      "value": "14'-1\"",
      "unit": "",
      "appliesTo": "lower bridge"
    },
    {
      "label": "total length of bridge",
      "value": "192'-0\"",
      "unit": "",
      "appliesTo": "bridge"
    },
    {
      "label": "span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "bridge"
    },
    {
      "label": "span length",
      "value": "82'-0\"",
      "unit": "",
      "appliesTo": "bridge"
    },
    {
      "label": "span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": "bridge"
    },
    {
      "label": "grade",
      "value": "+5.4180%",
      "unit": "",
      "appliesTo": "partial proposed vertical profile"
    },
    {
      "label": "elevation",
      "value": "560",
      "unit": "",
      "appliesTo": "partial proposed vertical profile"
    },
    {
      "label": "grade",
      "value": "+5.4443%",
      "unit": "",
      "appliesTo": "partial proposed vertical profile"
    },
    {
      "label": "elevation",
      "value": "560",
      "unit": "",
      "appliesTo": "partial proposed vertical profile"
    }
  ],
  "notes": [
    "POINT OF MIN. VERT. CLEARANCE",
    "FUTURE POINT OF MIN. VERT. CLEARANCE",
    "TEMPORARY SHORING AS NECESSARY, TYP.",
    "TO BE REMOVED",
    "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN",
    "CHAIN LINK WIRE FENCE, TYP."
  ],
  "labels": [
    "TO US 25/SR 121",
    "TO GA HIGHWAY 23",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "B.F.P.R. BENT 1L",
    "B.F.P.R. BENT 4L",
    "B.F.P.R. BENT 1R",
    "B.F.P.R. BENT 4R",
    "BEGIN BRIDGE",
    "END BRIDGE",
    "PT#3",
    "RRMP D-0008.54",
    "TO PERKINS",
    "TO MILLEN",
    "PRR R/W",
    "PLAN",
    "PROPOSED VER...",
    "SR 21 PG...",
    "BENT ELEVATION",
    "LOCATION",
    "BENT NO.",
    "LEFT BRIDGE",
    "RIGHT BRIDGE"
  ],
  "description": "This crop is a plan view of two parallel, skewed bridge structures carrying SR 21 over the Central of Georgia Railroad Company alignment. It identifies left and right bridge bents, wall front faces, gutters, railroad tracks, clearance locations, stations, and bridge span lengths. A partial bent-elevation schedule and partial proposed vertical-profile graphics are visible at the right edge."
}

p01_r01 planPlan

  • temporary shoringlinearShown along the railroad crossing area; identified as typical/as necessary.