⚠ No class in the bridge ontology fits this itemAdd a class
The ontology would need a drip bead or drip edge class.
Every dimension read for it4
- 3”drip-bead offsetp5 · p05_r01 section thru slab
- 3"drip-bead dimensionp5 · p05_r01
- ¾"drip-bead sizep5 · p05_r01
- 2"partial adjacent view dimensionnot attributedp5 · p05_r01
Notes on the sheets that carry it
- p5DIMENSION “D” IS MEASURED FROM TOP OF SLAB TO TOP OF BEAMS AT CENTERLINE BEARING. VARY “D” BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTION, AND VERTICAL CURVE.
- p5MAINTAIN A CONSTANT SLAB THICKNESS OF 7¾” BETWEEN BEAMS AND 8” IN THE OVERHANGS.
- p5“D” = 8¾” INTERIOR BEAMS
- p5“D” = 9⅝” EXTERIOR BEAMS
- p5FENCE NOT SHOWN, TYP.
- p530-400A SPACED AS SHOWN
- p5502 AT EVERY 500A, TYP.
- p5500A AT 6½”
- p550I UNDER EVERY 500A
- p56-400A AT EQ. SPS.
- p514-400A AT EQUAL SPACES, TYP.
- p5REQUIRED CONSTRUCTION JOINT PARALLEL WITH DECK, TYP.
- p5¾” TRIANGULAR DRIP BEAD FULL LENGTH OF BRIDGE, TYP.
- p5501 UNDER EVERY 500A
Every crop it was read in — the drawing beside what the model took off it
Page 5
p05_r01 section thru slabCross Section
- triangular drip beadtriangularCalled out full length of bridge, typical.
8¾” dimension D, interior beams9⅝” dimension D, exterior beams7¾” constant slab thickness between beams8” slab thickness in overhangs1/2” edge dimension1’-8” edge offset43’-7” out to out width40’-0” gutter to gutter width+14 more
p05_r01Cross Section
- triangular drip bead×1triangularCalled out as full length of bridge, typical.
43'-7" out to out40'-0" gutter to gutter34'-0" left portion of deck width6'-0" right portion of deck width22'-0" width to right edge from PGL reference14'-2½" right-side width1'-8" edge offset1'-8" edge offset+25 more