Drawing → BOQ
← Mindmapwhat the drawings said

Expansion Joint

1 page · 1 crop · ×4 · deck

Matched toExpansion Joint Systembridge.superstructure.expansion_joint_systemon “Expansion Joint

This class asks for no measurements, so there is no take-off to do against it.

How the sheets named it

EXP.

Every dimension read for it12

  • 74'-7 15/16"Plan dimensionnot attributedp1 · bridge_1_right
  • 1'-9 1/2"Minimum vertical clearancenot attributedp1 · bridge_1_right
  • 40'-0"Gutter-to-gutter dimensionnot attributedp1 · bridge_1_right
  • 43'-7"Gutter-out-to-out dimensionnot attributedp1 · bridge_1_right
  • 6'-0"Plan dimensionnot attributedp1 · bridge_1_right
  • 34'-0"Plan dimensionnot attributedp1 · bridge_1_right
  • 22'-0"Plan dimensionnot attributedp1 · bridge_1_right
  • 14'-1" MIN.Minimum dimensionnot attributedp1 · bridge_1_right
  • 15'-0"Plan dimensionnot attributedp1 · bridge_1_right
  • 55'-0"Span lengthnot attributedp1 · bridge_1_right
  • 82'-0"Span lengthnot attributedp1 · bridge_1_right
  • 55'-0"Span lengthnot attributedp1 · bridge_1_right

Notes on the sheets that carry it

  • p11. ALL BENTS ARE PARALLEL TO ℄ CENTRAL OF GEORGIA RAILWAY COMPANY.
  • p12. END BENT PILES NOT SHOWN.
  • p1** 3. STATIONS ARE ALONG ℄ SR 21 AT INTERSECTI... AND B.F.P.R. OR ℄ BENT. ELEVATIONS ARE ALONG EASTBOUND AND WES... PROFILE GRADE LINES AT THE INTERSECTION OF ... PROFILE GRADE LINES AND B.F.P.R. OR CENTER...
  • p1*** 4. MEASURED ALONG ℄ SR 21.
  • p1* 5. LEFT BRIDGE: MINIMUM REQUIRED VERTICAL CLEARANCE = 23... EXISTING TRACK VERTICAL CLEARANCE CALCULA... FUTURE TRACK VERTICAL CLEARANCE CALCULA... RIGHT BRIDGE: MINIMUM REQUIRED VERTICAL CLEARANCE = 23... EXISTING TRACK VERTICAL CLEARANCE CALCUL... FUTURE TRACK VERTICAL CLEARANCE CALCULA...
  • p1** 6. MINIMUM REQUIRED HORIZONTAL CLEARANCE = ...
  • p1TEMPORARY SHORING AS NECESSARY, TYP.
  • p1CHAIN LINK WIRE FENCE, TYP.
  • p1TO BE REMOVED

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

bridge_1_right

page 1 · bridge_1_right
Original
bridge_1_right
{
  "view": "Unclear",
  "objects": [
    {
      "name": "Wall",
      "tag": "WALL 1",
      "shape": "rectangular",
      "material": "",
      "count": 2,
      "note": "Front face shown in plan and elevation."
    },
    {
      "name": "Wall",
      "tag": "WALL 2",
      "shape": "rectangular",
      "material": "",
      "count": 4,
      "note": "Front face shown in plan and elevation."
    },
    {
      "name": "Bent",
      "tag": "BENT 1L / BENT 1R",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "B.F.P.R. end bent locations shown; end bent piles not shown."
    },
    {
      "name": "Bent",
      "tag": "BENT 2L / BENT 2R",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "Interior bent locations shown."
    },
    {
      "name": "Bent",
      "tag": "BENT 3L / BENT 3R",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "Interior bent locations shown."
    },
    {
      "name": "Bent",
      "tag": "BENT 4L / BENT 4R",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "B.F.P.R. end bent locations shown; end bent piles not shown."
    },
    {
      "name": "Pile cap and piles",
      "tag": "",
      "shape": "rectangular pile cap with vertical piles",
      "material": "",
      "count": 2,
      "note": "Shown below Bents 2 and 3 in elevation."
    },
    {
      "name": "Bridge deck",
      "tag": "",
      "shape": "straight deck slab/profile",
      "material": "",
      "count": 1,
      "note": "Shown in elevation with PGL."
    },
    {
      "name": "Expansion joint",
      "tag": "EXP.",
      "shape": "",
      "material": "",
      "count": 4,
      "note": "Locations shown in elevation."
    },
    {
      "name": "Fixed bearing",
      "tag": "FIX",
      "shape": "",
      "material": "",
      "count": 2,
      "note": "Locations shown in elevation."
    },
    {
      "name": "Chain link wire fence",
      "tag": "",
      "shape": "mesh panel",
      "material": "wire",
      "count": 3,
      "note": "Labeled TYP."
    },
    {
      "name": "Existing track",
      "tag": "℄ EXISTING TRACK",
      "shape": "alignment",
      "material": "",
      "count": 1,
      "note": "Shown below bridge in elevation and in plan."
    },
    {
      "name": "Future track",
      "tag": "℄ FUTURE TRACK",
      "shape": "alignment",
      "material": "",
      "count": 1,
      "note": "Shown below bridge in elevation and in plan."
    },
    {
      "name": "Future access road",
      "tag": "℄ FUTURE ACCESS ROAD",
      "shape": "alignment",
      "material": "",
      "count": 1,
      "note": "Shown in plan and elevation."
    },
    {
      "name": "Future groundline",
      "tag": "",
      "shape": "irregular line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Approximate existing groundline",
      "tag": "",
      "shape": "irregular line",
      "material": "",
      "count": 1,
      "note": ""
    },
    {
      "name": "Temporary shoring",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "As necessary, TYP."
    }
  ],
  "measurements": [
    {
      "label": "Minimum dimension",
      "value": "12'-1\" MIN.",
      "unit": "",
      "appliesTo": "℄ CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK"
    },
    {
      "label": "Plan dimension",
      "value": "74'-7 15/16\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Plan dimension",
      "value": "75'-10 15/16\"",
      "unit": "",
      "appliesTo": "℄ FUTURE TRACK"
    },
    {
      "label": "Plan dimension",
      "value": "N. 2°-23'-16.7\"",
      "unit": "",
      "appliesTo": "AHEAD"
    },
    {
      "label": "Minimum vertical clearance",
      "value": "1'-9 1/2\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Gutter-to-gutter dimension",
      "value": "40'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Gutter-out-to-out dimension",
      "value": "43'-7\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Plan dimension",
      "value": "6'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Plan dimension",
      "value": "34'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Angle",
      "value": "81°-20'-05.0\"",
      "unit": "",
      "appliesTo": "Bents"
    },
    {
      "label": "Station",
      "value": "STA. 18+16.85",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "Station",
      "value": "STA. 303+80.83",
      "unit": "",
      "appliesTo": "℄ CENTRAL OF GEORGIA RAILROAD COMPANY"
    },
    {
      "label": "Begin bridge station",
      "value": "STA. 17+23.00",
      "unit": "",
      "appliesTo": "BEGIN BRIDGE"
    },
    {
      "label": "Station",
      "value": "STA. 17+29.07",
      "unit": "",
      "appliesTo": "RRMP D-0080.54"
    },
    {
      "label": "Station",
      "value": "STA. 19+08.93",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "End bridge station",
      "value": "STA. 19+15.00",
      "unit": "",
      "appliesTo": "END BRIDGE"
    },
    {
      "label": "Bearing",
      "value": "N. 83°-43'-21.7\" E.",
      "unit": "",
      "appliesTo": "℄ SR 21"
    },
    {
      "label": "Plan dimension",
      "value": "22'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Minimum dimension",
      "value": "14'-1\" MIN.",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Plan dimension",
      "value": "15'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Plan dimension",
      "value": "25'-8\"",
      "unit": "",
      "appliesTo": "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN"
    },
    {
      "label": "Plan dimension",
      "value": "36'-4\"",
      "unit": "",
      "appliesTo": "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN"
    },
    {
      "label": "Total bridge length",
      "value": "192'-0\"",
      "unit": "",
      "appliesTo": "Bridge"
    },
    {
      "label": "Span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Span length",
      "value": "82'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Span length",
      "value": "55'-0\"",
      "unit": "",
      "appliesTo": ""
    },
    {
      "label": "Elevation",
      "value": "EL. 151.00",
      "unit": "",
      "appliesTo": "Pile caps"
    },
    {
      "label": "Station",
      "value": "17+26.35",
      "unit": "",
      "appliesTo": "LEFT BRIDGE BENT 1"
    },
    {
      "label": "Station",
      "value": "17+81.35",
      "unit": "",
      "appliesTo": "LEFT BRIDGE BENT 2"
    },
    {
      "label": "Station",
      "value": "18+63.35",
      "unit": "",
      "appliesTo": "LEFT BRIDGE BENT 3"
    },
    {
      "label": "Station",
      "value": "19+18.35",
      "unit": "",
      "appliesTo": "LEFT BRIDGE BENT 4"
    },
    {
      "label": "Station",
      "value": "17+19.65",
      "unit": "",
      "appliesTo": "RIGHT BRIDGE BENT 1"
    },
    {
      "label": "Station",
      "value": "17+74.65",
      "unit": "",
      "appliesTo": "RIGHT BRIDGE BENT 2"
    },
    {
      "label": "Station",
      "value": "18+56.65",
      "unit": "",
      "appliesTo": "RIGHT BRIDGE BENT 3"
    },
    {
      "label": "Station",
      "value": "19+11.65",
      "unit": "",
      "appliesTo": "RIGHT BRIDGE BENT 4"
    },
    {
      "label": "PVI station",
      "value": "PVI STA. 18+10.00",
      "unit": "",
      "appliesTo": "SR 21 PGL profile fragment"
    },
    {
      "label": "PVI elevation",
      "value": "EL. 197.80",
      "unit": "",
      "appliesTo": "SR 21 PGL profile fragment"
    },
    {
      "label": "Grade",
      "value": "+5.4180%",
      "unit": "",
      "appliesTo": "SR 21 PGL profile fragment"
    },
    {
      "label": "Grade length",
      "value": "560.0 FT.",
      "unit": "FT.",
      "appliesTo": "SR 21 PGL profile fragment"
    },
    {
      "label": "Grade",
      "value": "+5.4443%",
      "unit": "",
      "appliesTo": "SR 21 PGL profile fragment"
    }
  ],
  "notes": [
    "1. ALL BENTS ARE PARALLEL TO ℄ CENTRAL OF GEORGIA RAILWAY COMPANY.",
    "2. END BENT PILES NOT SHOWN.",
    "** 3. STATIONS ARE ALONG ℄ SR 21 AT INTERSECTI... AND B.F.P.R. OR ℄ BENT. ELEVATIONS ARE ALONG EASTBOUND AND WES... PROFILE GRADE LINES AT THE INTERSECTION OF ... PROFILE GRADE LINES AND B.F.P.R. OR CENTER...",
    "*** 4. MEASURED ALONG ℄ SR 21.",
    "* 5. LEFT BRIDGE: MINIMUM REQUIRED VERTICAL CLEARANCE = 23... EXISTING TRACK VERTICAL CLEARANCE CALCULA... FUTURE TRACK VERTICAL CLEARANCE CALCULA... RIGHT BRIDGE: MINIMUM REQUIRED VERTICAL CLEARANCE = 23... EXISTING TRACK VERTICAL CLEARANCE CALCUL... FUTURE TRACK VERTICAL CLEARANCE CALCULA...",
    "** 6. MINIMUM REQUIRED HORIZONTAL CLEARANCE = ...",
    "TEMPORARY SHORING AS NECESSARY, TYP.",
    "CHAIN LINK WIRE FENCE, TYP.",
    "TO BE REMOVED"
  ],
  "labels": [
    "PLAN",
    "ELEVATION",
    "BENT ELEVATIONS **",
    "LOCATION",
    "BENT NO.",
    "STATION",
    "LEFT BRIDGE",
    "RIGHT BRIDGE",
    "PGL WESTBOUND",
    "PGL EASTBOUND",
    "PGL",
    "℄ CENTRAL OF GEORGIA RAILROAD COMPANY EXISTING TRACK",
    "℄ FUTURE ACCESS ROAD",
    "℄ FUTURE TRACK",
    "℄ EXISTING TRACK",
    "TO PERKINS",
    "TO US 25/SR 121",
    "TO GA HIGHWAY 23",
    "BEGIN BRIDGE",
    "END BRIDGE",
    "POINT OF MIN. VERT. CLEARANCE",
    "FUTURE POINT OF MIN. VERT. CLEARANCE",
    "MIN. HORIZ. CL. CALCULATED TO FACE OF COLUMN",
    "NOTES:"
  ],
  "description": "This crop contains a bridge general arrangement with a plan at the top and an elevation at the bottom, rather than a single elevation view. It documents left and right bridge bent positions, walls, deck bearing/joint locations, railroad and future-track clearances, bridge length and bent-station information. The right edge includes a partial proposed vertical profile and a bent-elevations table; some note text is cut off by the crop boundary."
}

bridge_1_rightUnclear

  • Expansion jointEXP.×4Locations shown in elevation.

12'-1" MIN. Minimum dimension74'-7 15/16" Plan dimension75'-10 15/16" Plan dimensionN. 2°-23'-16.7" Plan dimension1'-9 1/2" Minimum vertical clearance40'-0" Gutter-to-gutter dimension43'-7" Gutter-out-to-out dimension6'-0" Plan dimension+32 more