Drawing → BOQ
← Mindmapwhat the drawings said

Bituminous Concrete Layer

1 page · 1 crop · pavement

Matched toWearing Coursebridge.superstructure.deck_system.wearing_coursecheckon “Bituminous

2 read off the drawings · 2 not established
The class asks forValueHowFrom
LengthLwants m/mmnot establishedThe only crop for this item is a general notes block giving thickness and material only; no plan dimension or bridge/deck length is given for the bituminous concrete layer, and no other geometry (e.g., deck length) is stated in this reading to derive it from.not found
WidthWwants m/mmnot establishedNo carriageway or deck width dimension is provided in the notes crop; nothing to derive width from for the bituminous concrete layer.not found
Layer ThicknessT_layerwants m/mm50 mmDirectly stated: 'BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER' and measurement entry 'Bituminous concrete thickness = 50 MM'.The note explicitly states the bituminous concrete layer thickness as 50mm, laid in a single layer, directly assigned to this item.readp2 · p02_r06 notes of general design notes
Material TypeMATBituminous concrete -Object entry names the material as 'bituminous concrete' explicitly for the 'Bituminous concrete layer' item.readp2 · p02_r06 notes of general design notes

Worked out by anthropic/claude-sonnet-5 from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

Every dimension read for it1

  • 50 MMBituminous concrete thicknessp2 · p02_r06 notes of general design notes

Notes on the sheets that carry it

  • p2ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
  • p2DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
  • p2THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
  • p2THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
  • p2GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- PSC PRECAST GIRDER-M50; R.C.C. CAST IN SITU DECK SLAB-M45; R.C.C. END CROSS GIRDER-M45; R.C.C. INTERMEDIATE CROSS GIRDER-M45; BEARING PEDESTAL-M50; CRASH BARRIER-M40; APPROACH SLAB-M30; LEVELLING COURSE-M15; DIRT WALL & SLAB-M35; ABUTMENT & PIER-M45; PILE FOUNDATION-M35.
  • p2CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION...75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP...45mm, PIER & PIER CAP...45mm; SUPERSTRUCTURE...45mm.
  • p2ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.
  • p2STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.
  • p2BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.
  • p2FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.
  • p2DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.
  • p2BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.
  • p2THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.
  • p2DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.
  • p2THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°, γ=2T/m3
  • p2THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.
  • p2FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.
  • p2TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-

Every crop it was read in — the drawing beside what the model took off it

Page 2

crop

p02_r06 notes of general design notes

page 2 · structural_drawings_pkg_1_890ff33d80e843ef8aa5a52a7a9de3d8_p02_r06_notes_of_general_design_notes
Original
p02_r06 notes of general design notes
{
  "view": "Notes",
  "objects": [
    {
      "name": "PSC precast girder",
      "tag": "",
      "shape": "",
      "material": "precast concrete",
      "count": null,
      "note": "Referenced in concrete grade note (M50)"
    },
    {
      "name": "R.C.C. cast in situ deck slab",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade M45"
    },
    {
      "name": "R.C.C. end cross girder",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade M45"
    },
    {
      "name": "R.C.C. intermediate cross girder",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade M45"
    },
    {
      "name": "Bearing pedestal",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade M50"
    },
    {
      "name": "Crash barrier",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade M40"
    },
    {
      "name": "Approach slab",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade M30"
    },
    {
      "name": "Levelling course",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade M15"
    },
    {
      "name": "Dirt wall & slab",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": null,
      "note": "Concrete grade M35"
    },
    {
      "name": "Abutment",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade M45; part of abutment & pier group"
    },
    {
      "name": "Pier",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade M45; part of abutment & pier group"
    },
    {
      "name": "Pile foundation",
      "tag": "",
      "shape": "",
      "material": "reinforced concrete",
      "count": null,
      "note": "Concrete grade M35"
    },
    {
      "name": "Expansion joint",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Strip seal type as per MORTH specification"
    },
    {
      "name": "Drainage spout",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Provided in deck slab per MORTH specification"
    },
    {
      "name": "Bituminous concrete layer",
      "tag": "",
      "shape": "",
      "material": "bituminous concrete",
      "count": null,
      "note": "50mm thick, single layer"
    },
    {
      "name": "RE wall / backfill",
      "tag": "",
      "shape": "",
      "material": "selected earth fill",
      "count": null,
      "note": "Behind RE wall, properties C=0, phi>32°, gamma=2T/m3"
    },
    {
      "name": "Gap slab",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Referenced for dimension & reinforcement details in miscellaneous drawing"
    },
    {
      "name": "Pile",
      "tag": "",
      "shape": "",
      "material": "",
      "count": null,
      "note": "Tentative working pile load table given"
    }
  ],
  "measurements": [
    {
      "label": "Clear cover - Foundation",
      "value": "75",
      "unit": "mm",
      "appliesTo": "Foundation"
    },
    {
      "label": "Clear cover - Abutment & Abutment Cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Abutment"
    },
    {
      "label": "Clear cover - Pier & Pier Cap",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Pier"
    },
    {
      "label": "Clear cover - Superstructure",
      "value": "45",
      "unit": "mm",
      "appliesTo": "Superstructure"
    },
    {
      "label": "Bituminous concrete thickness",
      "value": "50",
      "unit": "MM",
      "appliesTo": "Bituminous concrete layer"
    },
    {
      "label": "Bearing/pedestal depth basis",
      "value": "400",
      "unit": "mm",
      "appliesTo": "Pier cap / Bearing pedestal"
    },
    {
      "label": "Minimum bearing height threshold",
      "value": "200",
      "unit": "mm",
      "appliesTo": "Bearing"
    },
    {
      "label": "Pedestal adjustment height",
      "value": "200",
      "unit": "mm",
      "appliesTo": "Pedestal"
    },
    {
      "label": "Max vertical pile load",
      "value": "300",
      "unit": "T",
      "appliesTo": "Pile"
    },
    {
      "label": "Lateral pile load",
      "value": "50",
      "unit": "T",
      "appliesTo": "Pile"
    },
    {
      "label": "Selected earth fill cohesion",
      "value": "0",
      "unit": "",
      "appliesTo": "RE wall backfill"
    },
    {
      "label": "Selected earth fill friction angle",
      "value": ">32",
      "unit": "degrees",
      "appliesTo": "RE wall backfill"
    },
    {
      "label": "Selected earth fill unit weight",
      "value": "2",
      "unit": "T/m3",
      "appliesTo": "RE wall backfill"
    }
  ],
  "notes": [
    "ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.",
    "DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.",
    "THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.",
    "THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.",
    "GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- PSC PRECAST GIRDER-M50; R.C.C. CAST IN SITU DECK SLAB-M45; R.C.C. END CROSS GIRDER-M45; R.C.C. INTERMEDIATE CROSS GIRDER-M45; BEARING PEDESTAL-M50; CRASH BARRIER-M40; APPROACH SLAB-M30; LEVELLING COURSE-M15; DIRT WALL & SLAB-M35; ABUTMENT & PIER-M45; PILE FOUNDATION-M35.",
    "CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION...75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP...45mm, PIER & PIER CAP...45mm; SUPERSTRUCTURE...45mm.",
    "ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.",
    "STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.",
    "BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.",
    "FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.",
    "DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.",
    "BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.",
    "THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.",
    "DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.",
    "THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°, γ=2T/m3",
    "THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.",
    "FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.",
    "TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-"
  ],
  "labels": [
    "NOTES:",
    "MAX. VERTICAL LOAD",
    "LATERAL LOAD"
  ],
  "description": "This crop is a general notes block (Sheet page 2) for a bridge project, listing 18 numbered construction notes covering dimensioning conventions, live load design basis, concrete grades for each structural component, reinforcement clear cover requirements, rebar material specification, expansion joint and drainage spout provisions, backfilling requirements, seismic/wind zone classification, and a tentative pile load table. It contains no plan, section, or elevation geometry, only textual specifications and a small load table (max vertical load 300T, lateral load 50T) applicable to pile foundations."
}

p02_r06 notes of general design notesNotes

  • Bituminous concrete layerbituminous concrete50mm thick, single layer

75 mm Clear cover - Foundation45 mm Clear cover - Abutment & Abutment Cap45 mm Clear cover - Pier & Pier Cap45 mm Clear cover - Superstructure50 MM Bituminous concrete thickness400 mm Bearing/pedestal depth basis200 mm Minimum bearing height threshold200 mm Pedestal adjustment height+5 more