Matched toAbutment Backwallbridge.substructure.abutment_system.backwallon “Dirt wall”
1 read off the drawings · 4 not established
| The class asks for | Value | How | From |
|---|---|---|---|
| LengthLwants m/mm | not establishedNo geometric drawing/section for the dirt wall is present in the reading; only a general notes block listing concrete grade is provided. No length dimension is given for the dirt wall. | not found | |
| Wall ThicknessT_wallwants m/mm | not establishedNo section or detail drawing of the dirt wall showing its thickness is present in the readings; only the notes crop with concrete grade is available. | not found | |
| HeightHwants m/mm | not establishedNo elevation or section detail giving the dirt wall height is present in the readings. | not found | |
| Instance CountNwants count | not establishedThe reading is a general notes block with no plan/count information for dirt walls (e.g., per abutment). No count is stated or derivable. | not found | |
| Concrete Gradefck | M35 -Directly stated in general notes: 'DIRT WALL & SLAB-M35'.The notes explicitly list the concrete grade for 'Dirt wall & slab' as M35, both in the object list and in the consolidated grade note sentence. | read | p2 · p02_r06 notes of general design notes |
Worked out by anthropic/claude-sonnet-5 from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.
How the sheets named it
Dirt wall & slab
Notes on the sheets that carry it
- p2ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED.
- p2DIMENSIONS ARE NOT TO BE SCALED. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
- p2THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RESPECTIVE HIGHWAY ALIGNMENT DRAWINGS.
- p2THE BRIDGE HAS BEEN DESIGNED FOR FOUR LANE OF CLASS A, ONE LANE CLASS 70R + TWO LANE OF CLASS A, ONE LANE OF 70R + ONE LANE OF 70R OR SV LOADING WHICHEVER GOVERNS, IS CONSIDERED AS LIVE LOAD.
- p2GRADE OF CONCRETE FOR VARIOUS STRUCTURAL COMPONENTS SHALL BE AS FOLLOWS:- PSC PRECAST GIRDER-M50; R.C.C. CAST IN SITU DECK SLAB-M45; R.C.C. END CROSS GIRDER-M45; R.C.C. INTERMEDIATE CROSS GIRDER-M45; BEARING PEDESTAL-M50; CRASH BARRIER-M40; APPROACH SLAB-M30; LEVELLING COURSE-M15; DIRT WALL & SLAB-M35; ABUTMENT & PIER-M45; PILE FOUNDATION-M35.
- p2CLEAR COVER TO ANY REINFORCEMENTS SHALL BE AS FOLLOWS: FOUNDATION...75mm; SUBSTRUCTURE ABUTMENT & ABUTMENT CAP...45mm, PIER & PIER CAP...45mm; SUPERSTRUCTURE...45mm.
- p2ALL REINFORCING STEEL SHOULD BE HIGH YIELD STRENGTH DEFORMED (TMT) BARS OF GRADE-Fe 550D, CONFORMING TO IS: 1786.
- p2STRIP SEAL TYE OF EXPANSION JOINT SHALL BE PROVIDED AS PER M O R T H SPECIFICATION.
- p2BITUMINOUS CONCRETE 50MM THICK LAID IN SINGLE LAYER.
- p2FRL, CAMBER / SUPER ELEVATION & LAYOUT SHALL BE FOLLOWED AS PER LATEST PLAN & PROFILE DRAWING.
- p2DRAINAGE SPOUT SHALL BE PROVIDED IN DECK SLAB AS PER M O R T H SPECIFICATION.
- p2BACK FILLING MATERIAL BEHIND ABUTMENT SHALL BE WELL COMPACTED AS PER APPENDIX 6 OF IRC 78:2014 & M O R T H SPECIFICATION BEFORE RESTING THE SUPERSTRUCTURE.
- p2THE STRUCTURE IS LOCATED IN SEISMIC ZONE III AND WIND ZONE IV & 'SEVERE' EXPOSURE CONDITION.
- p2DIMENSION OF STRUCTURES ARE TENTATIVE AND WILL BE FINALIZED AFTER DETAIL DESIGN.
- p2THE SELECTED EARTH FILL USED FOR BACKFILLING BEHIND RE WALL SHALL HAVE THE FOLLOWING PROPERTIES. C=0, ø>32°, γ=2T/m3
- p2THE PIERCAP TOP LEVEL HAS BEEN FIXED CONSIDERING 400mm DEPTH OF BRG. & PEDESTAL. IN CASE THE BEARING HEIGHT IS LESS THAN THAT OF 200mm THEN THE HEIGHT OF THE BEARING SHALL BE ADJUSTED IN 200mm PEDESTAL.
- p2FOR DIMENSION & REINFORCEMENT DETAILS OF APPROACH SLAB, GAP SLAB, CRASH BARRIER & DRAINAGE SPOUTS REFER MISCELLANEOUS DRG.
- p2TENTATIVE WORKING PILE LOAD AND SUBJECTED TO CHANGE AS PER DETAILED DESIGN:-
Every crop it was read in — the drawing beside what the model took off it
Page 2
crop
p02_r06 notes of general design notesNotes
- Dirt wall & slabconcreteConcrete grade M35
75 mm Clear cover - Foundation45 mm Clear cover - Abutment & Abutment Cap45 mm Clear cover - Pier & Pier Cap45 mm Clear cover - Superstructure50 MM Bituminous concrete thickness400 mm Bearing/pedestal depth basis200 mm Minimum bearing height threshold200 mm Pedestal adjustment height+5 more