Drawing → BOQ
← Mindmapwhat the drawings said

Pavement Layer

1 page · 1 crop · ×2 · pavement

⚠ No class in the bridge ontology fits this itemAdd a class

Generic PCC pavement layer does not fit wearing course (asphalt) or blinding concrete (foundation); ontology lacks a generic pavement layer class.

Notes on the sheets that carry it

  • p21. ALL DIMENSIONS ARE ... OTHERWISE SPECIFIED.
  • p22. DIMENSIONS ARE NOT FOLLOWED.
  • p23. THIS DRAWING SHALL ALIGNMENT DRAWINGS
  • p24. THE BRIDGE HAS PER... (text cut off)

Every crop it was read in — the drawing beside what the model took off it

Page 2

crop

p02_r02

page 2 · bridge_superstructure_spans_p02_r02
Original
p02_r02
{
  "view": "Elevation",
  "objects": [
    {
      "name": "Abutment",
      "tag": "A1",
      "shape": "wall type",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Wall type abutment at left end, with expansion joint and bearing"
    },
    {
      "name": "Abutment",
      "tag": "A2",
      "shape": "wall type",
      "material": "reinforced concrete",
      "count": 1,
      "note": "Wall type abutment at right end, mirrors A1"
    },
    {
      "name": "Pier",
      "tag": "P1",
      "shape": "circular column",
      "material": "reinforced concrete",
      "count": 1,
      "note": "RCC column pier at centre, labelled RCC COLUMN PIER (TYP.)"
    },
    {
      "name": "Bearing",
      "tag": "FR",
      "shape": "rectangular",
      "material": "PTFE/elastomeric pot bearing",
      "count": 3,
      "note": "POT-PTFE BEARING (TYP.), fixed/free type marked FR, located at A1, P1(one side) and A2"
    },
    {
      "name": "Bearing",
      "tag": "FX",
      "shape": "rectangular",
      "material": "PTFE pot bearing",
      "count": 1,
      "note": "POT-PTFE BEARING (TYP.), fixed type marked FX at pier P1"
    },
    {
      "name": "Girder",
      "tag": "",
      "shape": "I-girder/precast",
      "material": "precast concrete",
      "count": null,
      "note": "PRECAST PSC GIRDER (TYP.), multiple spans, exact count not enumerable from crop"
    },
    {
      "name": "Crash Barrier",
      "tag": "",
      "shape": "rectangular",
      "material": "reinforced concrete",
      "count": 2,
      "note": "RCC CRASH BARRIER along both spans"
    },
    {
      "name": "Approach Slab",
      "tag": "",
      "shape": "rectangular slab",
      "material": "concrete",
      "count": 2,
      "note": "300 THK. APPROACH SLAB at both ends"
    },
    {
      "name": "Pavement Layer",
      "tag": "",
      "shape": "layer",
      "material": "PCC",
      "count": 2,
      "note": "150 THK. PCC LEVELING COURSE beneath approach slabs"
    },
    {
      "name": "Retaining Wall",
      "tag": "",
      "shape": "rectangular/independent",
      "material": "concrete",
      "count": 2,
      "note": "INDEPENDENT RETAINING WALL shown both sides with stone pitching and filter media"
    },
    {
      "name": "Stone Pitching",
      "tag": "",
      "shape": "sloped surface treatment",
      "material": "stone",
      "count": 2,
      "note": "STONE PITCHING noted at both embankments"
    },
    {
      "name": "Filter Media",
      "tag": "",
      "shape": "layer",
      "material": "granular fill",
      "count": 2,
      "note": "600 THK. FILTER MEDIA beneath stone pitching"
    },
    {
      "name": "Pile",
      "tag": "",
      "shape": "circular",
      "material": "reinforced concrete, cast in situ",
      "count": null,
      "note": "1200Ø RCC CAST IN SITU PILE (TYP.) shown below pier P1 in dashed foundation plan; number of piles not clearly countable"
    },
    {
      "name": "Launching Apron",
      "tag": "",
      "shape": "sloped/stepped",
      "material": "stone/concrete",
      "count": 1,
      "note": "Shown below abutment A1 slope, labelled LAUNCHING APRON"
    },
    {
      "name": "Deck Continuity",
      "tag": "",
      "shape": "",
      "material": "concrete",
      "count": 1,
      "note": "Labelled DECK CONTINUITY at pier P1 location"
    },
    {
      "name": "Expansion Joint",
      "tag": "",
      "shape": "linear gap",
      "material": "",
      "count": 2,
      "note": "Marked at both abutments, EXP. GAP dimensions given"
    }
  ],
  "measurements": [
    {
      "label": "Span length (square)",
      "value": "40000",
      "unit": "",
      "appliesTo": "Span A1-P1"
    },
    {
      "label": "Span length (skew)",
      "value": "46188",
      "unit": "",
      "appliesTo": "Span A1-P1"
    },
    {
      "label": "Span length (square)",
      "value": "46000",
      "unit": "",
      "appliesTo": "Span P1-A2 (SK label shown twice, 46000(SQ) not explicit, only SK shown)"
    },
    {
      "label": "Span length (skew)",
      "value": "46188",
      "unit": "",
      "appliesTo": "Span P1-A2"
    },
    {
      "label": "Expansion gap (square)",
      "value": "80",
      "unit": "",
      "appliesTo": "A1 exp. joint"
    },
    {
      "label": "Expansion gap (skew)",
      "value": "92",
      "unit": "",
      "appliesTo": "A1 exp. joint"
    },
    {
      "label": "Expansion gap (square)",
      "value": "80",
      "unit": "",
      "appliesTo": "A2 exp. joint"
    },
    {
      "label": "Expansion gap (skew)",
      "value": "92",
      "unit": "",
      "appliesTo": "A2 exp. joint"
    },
    {
      "label": "Distance from exp joint to bearing centre (square)",
      "value": "1070",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "Distance from exp joint to bearing centre (skew)",
      "value": "1236",
      "unit": "",
      "appliesTo": "A1"
    },
    {
      "label": "Distance from exp joint to bearing centre (square)",
      "value": "1070",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "Distance from exp joint to bearing centre (skew)",
      "value": "1236",
      "unit": "",
      "appliesTo": "A2"
    },
    {
      "label": "Distance between bearings (square)",
      "value": "37761",
      "unit": "",
      "appliesTo": "Span A1-P1"
    },
    {
      "label": "Distance between bearings (skew)",
      "value": "43602",
      "unit": "",
      "appliesTo": "Span A1-P1"
    },
    {
      "label": "Distance between bearings (square)",
      "value": "37761",
      "unit": "",
      "appliesTo": "Span P1-A2"
    },
    {
      "label": "Distance between bearings (skew)",
      "value": "43602",
      "unit": "",
      "appliesTo": "Span P1-A2"
    },
    {
      "label": "Bearing offset at pier (square)",
      "value": "1170",
      "unit": "",
      "appliesTo": "P1 left"
    },
    {
      "label": "Bearing offset at pier (skew)",
      "value": "1350",
      "unit": "",
      "appliesTo": "P1 left"
    },
    {
      "label": "Bearing offset at pier (square)",
      "value": "1170",
      "unit": "",
      "appliesTo": "P1 right"
    },
    {
      "label": "Bearing offset at pier (skew)",
      "value": "1350",
      "unit": "",
      "appliesTo": "P1 right"
    },
    {
      "label": "Pier cap width (skew)",
      "value": "1500",
      "unit": "",
      "appliesTo": "P1 pier cap"
    },
    {
      "label": "Approach slab thickness",
      "value": "300",
      "unit": "THK.",
      "appliesTo": "Approach slab"
    },
    {
      "label": "PCC leveling course thickness",
      "value": "150",
      "unit": "THK.",
      "appliesTo": "PCC leveling course"
    },
    {
      "label": "Filter media thickness",
      "value": "600",
      "unit": "THK.",
      "appliesTo": "Retaining wall filter media"
    },
    {
      "label": "Minimum clearance",
      "value": "1200",
      "unit": "(min)",
      "appliesTo": "HFL clearance below girder"
    },
    {
      "label": "High Flood Level",
      "value": "HFL=",
      "unit": "",
      "appliesTo": "River/waterway (value not printed)"
    },
    {
      "label": "Low Water Level",
      "value": "506.000",
      "unit": "m",
      "appliesTo": "LWL"
    },
    {
      "label": "Pile diameter",
      "value": "1200",
      "unit": "mm (Ø)",
      "appliesTo": "RCC cast in situ pile"
    },
    {
      "label": "Pile cap/foundation dimension",
      "value": "750",
      "unit": "",
      "appliesTo": "P1 foundation"
    },
    {
      "label": "Pile spacing",
      "value": "3600",
      "unit": "",
      "appliesTo": "P1 foundation"
    },
    {
      "label": "Foundation width total",
      "value": "5100",
      "unit": "",
      "appliesTo": "P1 foundation"
    },
    {
      "label": "Embankment/retaining wall dimension",
      "value": "750",
      "unit": "",
      "appliesTo": "A1 retaining wall footing"
    },
    {
      "label": "Embankment dimension",
      "value": "3600",
      "unit": "",
      "appliesTo": "A1 retaining wall (repeated 3 times)"
    },
    {
      "label": "Embankment total width",
      "value": "12300",
      "unit": "",
      "appliesTo": "A1 retaining wall"
    },
    {
      "label": "Embankment/retaining wall dimension",
      "value": "750",
      "unit": "",
      "appliesTo": "A2 retaining wall footing"
    },
    {
      "label": "Embankment dimension",
      "value": "3600",
      "unit": "",
      "appliesTo": "A2 retaining wall (repeated 3 times)"
    },
    {
      "label": "Embankment total width",
      "value": "12300",
      "unit": "",
      "appliesTo": "A2 retaining wall"
    },
    {
      "label": "Chainage LHS point 1",
      "value": "64+360.197",
      "unit": "km",
      "appliesTo": "Table LHS chainage"
    },
    {
      "label": "Chainage RHS point 1",
      "value": "64+371.487",
      "unit": "km",
      "appliesTo": "Table RHS chainage"
    },
    {
      "label": "Chainage LHS point 2",
      "value": "64+406.385",
      "unit": "km",
      "appliesTo": "Table LHS chainage"
    },
    {
      "label": "Chainage RHS point 2",
      "value": "64+417.675",
      "unit": "km",
      "appliesTo": "Table RHS chainage"
    },
    {
      "label": "Chainage LHS point 3",
      "value": "64+452.573",
      "unit": "km",
      "appliesTo": "Table LHS chainage"
    },
    {
      "label": "Chainage RHS point 3",
      "value": "64+463.814",
      "unit": "km",
      "appliesTo": "Table RHS chainage"
    },
    {
      "label": "FRL LHS point 1",
      "value": "518.281",
      "unit": "m",
      "appliesTo": "Table FRL LHS"
    },
    {
      "label": "FRL RHS point 1",
      "value": "518.465",
      "unit": "m",
      "appliesTo": "Table FRL RHS"
    },
    {
      "label": "FRL LHS point 2",
      "value": "519.033",
      "unit": "m",
      "appliesTo": "Table FRL LHS"
    },
    {
      "label": "FRL RHS point 2",
      "value": "519.217",
      "unit": "m",
      "appliesTo": "Table FRL RHS"
    },
    {
      "label": "FRL LHS point 3",
      "value": "519.785",
      "unit": "m",
      "appliesTo": "Table FRL LHS"
    },
    {
      "label": "FRL RHS point 3",
      "value": "519.968",
      "unit": "m",
      "appliesTo": "Table FRL RHS"
    },
    {
      "label": "Ground level LHS point 1",
      "value": "509.560",
      "unit": "m",
      "appliesTo": "Table ground level LHS"
    },
    {
      "label": "Ground level LHS point 2",
      "value": "503.816",
      "unit": "m",
      "appliesTo": "Table ground level LHS"
    },
    {
      "label": "Ground level LHS point 3",
      "value": "511.891",
      "unit": "m",
      "appliesTo": "Table ground level LHS"
    }
  ],
  "notes": [
    "1. ALL DIMENSIONS ARE ... OTHERWISE SPECIFIED.",
    "2. DIMENSIONS ARE NOT FOLLOWED.",
    "3. THIS DRAWING SHALL ALIGNMENT DRAWINGS",
    "4. THE BRIDGE HAS PER... (text cut off)"
  ],
  "labels": [
    "TO DEWAS",
    "TO KHANDWA",
    "A1",
    "A2",
    "P1",
    "Ç OF EXP. JOINT",
    "Ç OF BRG.",
    "RCC CRASH BARRIER",
    "PRECAST PSC GIRDER (TYP.)",
    "WALL TYPE ABUTMENT",
    "POT-PTFE BEARING (TYP.)",
    "RCC COLUMN PIER (TYP.)",
    "DECK CONTINUITY",
    "LAUNCHING APRON",
    "STONE PITCHING",
    "INDEPENDENT RETAINING WALL",
    "300 THK. APPROACH SLAB",
    "150 THK. PCC LEVELING COURSE",
    "600 THK. FILTER MEDIA",
    "1200Ø RCC CAST IN SITU PILE (TYP.)",
    "LWL=506.000m",
    "HFL=",
    "NOTES:",
    "CHAINAGE IN (km.)",
    "FRL. (m)",
    "MAIN CARRIAGEWAY",
    "GROUND LEVEL(m)",
    "LHS",
    "RHS"
  ],
  "description": "This crop shows a full bridge elevation between two abutments (A1, A2) and a central pier (P1), depicting two spans of precast PSC girders on POT-PTFE bearings, RCC crash barriers, wall-type abutments, and a circular RCC column pier founded on 1200mm diameter cast-in-situ piles. Below the elevation is a data table listing chainage, formation road level, and ground level values at three points along LHS and RHS of the carriageway, with a partially visible general notes column at the right edge."
}

p02_r02Elevation

  • Pavement Layer×2layerPCC150 THK. PCC LEVELING COURSE beneath approach slabs

40000 Span length (square)46188 Span length (skew)46000 Span length (square)46188 Span length (skew)80 Expansion gap (square)92 Expansion gap (skew)80 Expansion gap (square)92 Expansion gap (skew)+44 more