Drawing → BOQ
← Mindmapwhat the drawings said

Utility Pipe/Duct

1 page · 1 crop · ×1 · drainage

Matched toUtility Ductbridge.ancillary_system.utility_ducton “Utility Pipe/Duct

2 read off the drawings · 1 derived · 1 not established
The class asks forValueHowFrom
LengthLwants m/mmnot establishedThe key plan shows the utility duct/RCC pipe running parallel to the road near CH 64+500 but gives no start/end chainage or length dimension for the pipe itself; only the road chainage markers (64+400, 64+500) are shown, which do not define the pipe's extent.not found
Drain DiameterD_drainwants mm600 mm0.6 m = 0.6 × 1000 mm = 600 mmThe reading explicitly states 'UTILITY DUCT / RCC PIPE (0.6m DIA)' and a measurement entry 'Utility duct/pipe diameter: 0.6 m' applied to 'Utility Duct/RCC Pipe', which is this item. Converted from m to mm per unit requirement.derivedp1 · p01_r01 site key plan showing row and road alignment
Instance CountNwants count1 countObject entry 'Utility Pipe/Duct' has count: 1The object list explicitly gives a count of 1 for the Utility Pipe/Duct object shown in the key plan.readp1 · p01_r01 site key plan showing row and road alignment
Material TypeMATRCC -The label text reads 'UTILITY DUCT / RCC PIPE (0.6m DIA)', explicitly naming the pipe material as RCC (Reinforced Cement Concrete).readp1 · p01_r01 site key plan showing row and road alignment

Worked out by anthropic/claude-sonnet-5 from the readings below, which are the source. A derived value shows its arithmetic — check it against the drawing before it is priced.

Notes on the sheets that carry it

  • p1PROPOSED CH: 64+412
  • p1STRUCTURE TYPE MJBR
  • p1PROPOSED SPAN 2X40m
  • p1SKEW 30°
  • p1PROPOSAL New Construction

Every crop it was read in — the drawing beside what the model took off it

Page 1

crop

p01_r01 site key plan showing row and road alignment

page 1 · structural_drawings_pkg_1_890ff33d80e843ef8aa5a52a7a9de3d8_p01_r01_site_key_plan_showing_row_and_road_alignment
Original
p01_r01 site key plan showing row and road alignment
{
  "view": "Plan",
  "objects": [
    {
      "name": "Roadway/Highway alignment",
      "tag": "",
      "shape": "linear, curved",
      "material": "",
      "count": 1,
      "note": "Runs diagonally across crop, connecting Dewas and Khandwa directions, crossing a river/nala shown by hatched area"
    },
    {
      "name": "Bridge/Structure (proposed)",
      "tag": "",
      "shape": "rectangular hatched zone",
      "material": "",
      "count": 1,
      "note": "Cross-hatched trapezoidal area over Shipra River indicating the proposed structure location per key plan table"
    },
    {
      "name": "Retaining/Toe Wall",
      "tag": "RET./TOE WALL",
      "shape": "linear",
      "material": "",
      "count": 2,
      "note": "Two callouts labeled 'RET./TOE WALL' on either side of the alignment"
    },
    {
      "name": "Right of Way boundary",
      "tag": "ROW",
      "shape": "linear",
      "material": "",
      "count": 4,
      "note": "Multiple ROW lines/labels bounding the corridor on both sides"
    },
    {
      "name": "Earthen Drain",
      "tag": "",
      "shape": "linear, sinuous",
      "material": "",
      "count": 1,
      "note": "Labeled 'Earthen Drain' near structure area"
    },
    {
      "name": "Utility Pipe/Duct",
      "tag": "",
      "shape": "circular (in plan, linear run)",
      "material": "",
      "count": 1,
      "note": "Text reads 'UTILITY DUCT / RCC PIPE (0.6m DIA)' running parallel to road near CH 64+500"
    },
    {
      "name": "River (Shipra River)",
      "tag": "",
      "shape": "irregular natural watercourse",
      "material": "",
      "count": 1,
      "note": "Labeled 'Shipra River' crossing under proposed structure"
    }
  ],
  "measurements": [
    {
      "label": "Proposed CH",
      "value": "64+412",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Structure Type",
      "value": "MJBR",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Proposed Span",
      "value": "2X40m",
      "unit": "m",
      "appliesTo": "Structure"
    },
    {
      "label": "Skew",
      "value": "30",
      "unit": "degrees",
      "appliesTo": "Structure"
    },
    {
      "label": "Proposal",
      "value": "New Construction",
      "unit": "",
      "appliesTo": "Structure"
    },
    {
      "label": "Chainage marker",
      "value": "64+400",
      "unit": "",
      "appliesTo": "Roadway alignment"
    },
    {
      "label": "Chainage marker",
      "value": "64+500",
      "unit": "",
      "appliesTo": "Roadway alignment"
    },
    {
      "label": "Utility duct/pipe diameter",
      "value": "0.6",
      "unit": "m",
      "appliesTo": "Utility Duct/RCC Pipe"
    },
    {
      "label": "Scale",
      "value": "1:2000",
      "unit": "",
      "appliesTo": "Key Plan drawing scale"
    }
  ],
  "notes": [
    "PROPOSED CH: 64+412",
    "STRUCTURE TYPE MJBR",
    "PROPOSED SPAN 2X40m",
    "SKEW 30°",
    "PROPOSAL New Construction"
  ],
  "labels": [
    "KEY PLAN",
    "(SCALE 1:2000)",
    "TO DEWAS",
    "TO KHANDWA",
    "ROW",
    "RET./ TOE WALL",
    "Shipra River",
    "Earthen Drain",
    "Agriculture Land",
    "N",
    "S",
    "E",
    "W",
    "64+400",
    "64+500"
  ],
  "description": "This is a Key Plan (scale 1:2000) showing the general layout of a proposed road/bridge crossing over the Shipra River, with chainages from approximately 64+400 to 64+500. It indicates the ROW boundaries, retaining/toe walls, an earthen drain, a utility duct/RCC pipe of 0.6m diameter, and a summary table giving the proposed structure's chainage (64+412), type (MJBR), span (2x40m), skew (30°), and proposal status (New Construction). The crop is an orientation/index drawing rather than a detailed structural plan."
}

p01_r01 site key plan showing row and road alignmentPlan

  • Utility Pipe/Duct×1circular (in plan, linear run)Text reads 'UTILITY DUCT / RCC PIPE (0.6m DIA)' running parallel to road near CH 64+500

64+412 Proposed CHMJBR Structure Type2X40m m Proposed Span30 degrees SkewNew Construction Proposal64+400 Chainage marker64+500 Chainage marker0.6 m Utility duct/pipe diameter+1 more